Page 1
! 0 0 T S C C 0 2 1 4 3 0 6 ! TOSHIBA 6-Slot Battery Charger B-EP800-CHG6-QM-R Owner's Manual...
Page 2
Before using the unit, please read this manual thoroughly and retain it for future reference. This symbol is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Page 4
PRÉCAUTIONS! 1. N’utilisez que les packs batteries Toshiba Tec conçus et fabriqués pour être utilisés avec ce modèle spécifique. Il y a un risque d’explosion si la batterie est remplacée par un modèle non adapté. Veuillez vous débarrasser des batteries usagées en respectant la réglementation.
Page 5
< Português > ATENÇÃO! 1. Utilize as baterias desenhadas e fabricadas pela Toshiba Tec especificamente para este modelo. Existe risco de explosão se for utilizado um tipo de bateria incorrecta. Desfaça-se das baterias usadas de acordo com as instruções. B-EP4DL-GH20-QM-R...
Page 6
English The following information is for EU-member states only: Disposal of products (based on EU-Directive 2002/96/EC, Directive on Waste electrical and electronic equipment – WEEE) The use of the symbol indicates that this product may not be disposed as unsorted municipal waste and has to be collected separately.
Page 7
Italiano Le seguenti informazioni sono solo gli stati membri della UE: Smaltimento del prodotto (basato sulla direttiva EU-Directive 2002/96/EC, Direttiva sullo smaltimento per il Riciclaggio delle Apparecchiature Elettriche od Elettroniche – RAEE – WEEE) Questo simbolo indica che i prodotti non possono essere smaltiti come rifiuti urbani non differenziati ma devono essere raccolti separatamente.
Page 8
If the plug supplied with this equipment has a detachable fuse cover, be sure to attach the fuse cover after you change the fuse. Never use the plug without the fuse cover. If you should lose the fuse cover, please contact your nearest TOSHIBA TEC service representative.
Page 9
WARNING! 1. To prevent fire or shock hazard, do not expose the unit to rain or moisture. 2. To avoid electrical shock, do not open the cover. 3. Refer servicing to qualified personnel only. 4. For indoor use only. 5. Do not use a spray cleaner containing flammable gas for cleaning this product, as this may cause a fire.
Page 10
• Do not place the unit in a location where it is: • Temperatures out of the specification • Dusty or dirty • Very humid • Vibrating If any difficulty should arise, unplug the unit and contact your Authorised TOSHIBA TEC representative.
To Charge the Battery Pack WARNING! 1. The B-EP800-CHG6-QM-R battery charger is exclusively used for the B-EP802- BT-QM-R/ B-804-BT-QM-R lithium-ion battery pack. DO NOT charge any other battery packs, or explosion, combustion, or overheating may result. 2. If the battery charger gives out smoke, a bad smell, or extraordinary heat, unplug the power cord from the outlet immediately.
2. Connect the AC adapter to the battery charger. Connect the power cord to the AC adapter. Connect the power cord to an AC outlet. Insert the battery pack into the slot in the orientation shown below. The CHARGE lamp will light up and charging will begin.
Charging time To charge an empty battery pack: Battery pack Charging time B-EP802-BT-QM-R about 3 hours (Until min. of 85% of the nominal capacity is charged.) B-EP804-BT-QM-R about 3 hours (Until min. of 85% of the nominal capacity is charged.) •...
If you have any problems during using this product, please check the following point first. If a problem cannot be solved by taking actions described below, unplug the battery charger and contact the dealer or an authorised TOSHIBA TEC service representative for assistance Symptom Cause and resolution •...
DC +19V, 7.89A (Supplied by the AC 100 to 240V AC, 50/60 Hz adapter) Output voltage: ------- DC 19V, 7.89A Application: TOSHIBA battery pack TOSHIBA 6-slot Battery B-EP802-BT-QM-R Charger B-EP804-BT-QM-R B-EP800-CHG6-QM-R Number of slots 6 slots (Every slot can charge a battery pack independently.)...