Electrical Parts - LG LW1214HR Service Manual

Hide thumbs Also See for LW1214HR:
Table of Contents

Advertisement

6. Shroud
1. Remove the fan. (Refer to section 5)
2. Remove the screw that fastens the shroud.
3. Remove the shroud. (See Figure 21)
4. Re-install the component by referring to the
removal procedure, above.

Electrical Parts

7. Overload Protector
1. Remove the cabinet. (Refer to section 2)
2. Remove the nut that fastens the terminal cover.
3. Remove the terminal cover. (See Figure 22)
4. Remove all the leads from the overload protec-
tor.
5. Remove the overload protector.
6. Re-install the component by referring to the
removal procedure, above.
8. Compressor
1. Remove the cabinet. (Refer to section 2)
2. Discharge the refrigerant system using a
Freon™ Recovery System.
If there is no valve to attach the recovery sys-
tem, install one (such as a Watco A-1) before
venting the Freon™.. Leave the valve in place
after servicing the system.
3. Remove the overload protector. (Refer to sec-
tion 7)
4. After purging the unit completely, unbraze the
suction and discharge tubes at the compressor
connections.
5. Remove the 3 nuts and the 3 washers that
fasten the compressor.
6. Remove the compressor. (See Figure 23)
7. Re-install the components by referring to the
removal procedure, above.
Disassembly
Figure 21
Figure 22
Figure 23
Service Manual 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents