Haier AP24DF1HRA Service Manual page 31

Packaged type dc inverter
Table of Contents

Advertisement

11.4.3 Indoor fan motor malfunction
Indoor Display
E14
Method of
The rotation speed detected by the Hall IC during fan motor operation is used to determine
Malfunction
abnormal fan motor operation
Detection
when the detected rotation feedback singal don't receiced in 2 minutes
Malfunction
Decision
Conditions
Operation halt due to breaking of wire inside the fan motor .
Supposed
Causes
Fan motor overheat protection
Operation halt due to breaking of the fan motor lead wires
Detection error due to faulty indoor unit PCB
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector,
How to check Fan Motor (DC)
Notes: the a/c is electrifying, don't pull out or insert the terminals of the
motor, else the motor would be damaged.
else parts damage may be occurred.
1. Check connector connection.
2. Check motor power supply voltage output (pins 1-4).
3. Check motor control voltage (pins 4-5).
4. Check rotation command voltage output (pins 4-6).
5. Check rotation pulse input (pins 4-7).
29
Seivice diagnosis
or
Domestic air conditioner

Advertisement

Table of Contents
loading

Table of Contents