INSTRUCTIONS FOR YOUR NEW MANASPORT
Noninvasive
UItrasound Stimulator
Customer Service
Toll Free: 888-508-0712
Email: CustomerService@manamed.net
Web: www.manamed.net
Manufactured For:
5240 W Charleston Blvd. , Las Vegas NV 89146
Document # IFU-MSPORT01-001, Rev. 1
Copyright 2022 ManaMed
, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MANASPORT and is the answer not in the manual?

Questions and answers

sherry l. fieman, md
February 14, 2025

What are the settings on this unit? mW, Faw, PRF, PW? Thank you.

Summary of Contents for Manamed MANASPORT

  • Page 1 INSTRUCTIONS FOR YOUR NEW MANASPORT Noninvasive UItrasound Stimulator Customer Service Toll Free: 888-508-0712 Email: CustomerService@manamed.net Web: www.manamed.net Manufactured For: 5240 W Charleston Blvd. , Las Vegas NV 89146 Document # IFU-MSPORT01-001, Rev. 1 ™ Copyright 2022 ManaMed , Inc.
  • Page 2: Table Of Contents

    ManaSport Expected Service/Shelf Life ........
  • Page 3: Purpose Of Device

    PURPOSE OF DEVICE The ManaSport is a portable and rechargeable prescriptive device. It is intended to be used for adults only, under the direction of a medical professional. The ManaSport is not intended for Home Use. INDICATIONS FOR USE Apply stationary use of ultrasound to: Generate deep heat within body tissues for the treatment of selected medical conditions such as the relief of pain, the relief of muscle spasms, the treatment of joint contractures, and the local increase in circulation.
  • Page 4: Precautions

    WARNINGS (continued) Do not use over sensitive skin areas or in the presence of poor circulation. The unattended use of this device by children or incapacitated persons may be dangerous. To reduce the risk of buns, electric shock, and fire, this device must be used in accordance with the instructions. Do not crush the device and its accessories.
  • Page 5: Quick Start Guide

    The ManaSport provides non-invasive therapy of low-intensity pulsed ultrasound for the treatment of selected sub-chronic and chronic medical conditions such as soft tissue injuries, shortened tendons due to past injuries and scar tissues, relief of pain, muscle spasms and joint contractures. ManaSport transmits a low-intensity ultrasound signal to the patient’s treatment site through ultrasound gel.
  • Page 6 QUICK START GUIDE (continued) The strap can provide you with a hand-free treatment. However, if you prefer to continuously move the transducer applicator throughout your treatment area, you can skip operations 2a to 4c, and only refer to Operation 4a at the bottom of this page. Specifically, please refer to the detailed instructions below for continuously moving the applicator.
  • Page 7 ManaSport Quantity of Treatment and Frequency of Use ManaSport should be used for 20 minutes per day or as prescribed by your doctor. The ultrasound will be automatically stopped after the maximum timer of 20 minutes runs out. It is very important to follow your physician/doctor’s protocol to get the full medical benefit of the treatment.
  • Page 8: User Maintenance

    ™ . The use of the wrong charger Refer to image of ManaSport for description of all components. can cause excessive heat, damage to the circuit and shorten the life of the battery. Do not attempt to connect the wall supply if any damage is noticed.
  • Page 9: Ultrasound Gel

    ULTRASOUND GEL Ultrasound gel is provided for use with ManaSport. Patients are instructed to place gel on the transducer applicator every time you use ManaSport. This gel allows the ultrasound signal to reach the depths of the treatment site through your skin. If the transducer applicator is not properly applied, the patient will receive an alert from the device.
  • Page 10: Troubleshooting

    Troubleshooting ManaSport will alert you by displaying an alert screen, if something is not working properly. See the following table for common alerts and problems as well as what to do if you get an alert or problem. If you get any other problem, do not try to fix ManaSport by yourself and contact customer service at 888-508-0712.
  • Page 11 The customer or the user of the ManaSport should assure that it is used in such an environment. Emissions Tests Compliance Electromagnetic Environment Guidance ManaSport uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause RF Emissions CISPR11 Group 1 any interference in nearby electronic equipment.
  • Page 12 TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to the fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the ManaSport is used exceeds the applicable RF compliance level above, the ManaSport should be observed to verify normal operation.