Summary of Contents for Abestorm Guardian SNS100

  • Page 1 User’s Manual Guardian SNS100 A b es t o r m Add: 8605 SANTA MONlCA BLVD#79525 WEST HOLLYWOOD,California,90069 USA E-mail: sales@abestorm.com Note: as we keep upgrading our product, we reserve the right to modify the product without notice in advance.
  • Page 4 • The inlet needs a minimum of 12” clearance and the discharge requires a minimum of 36” clearance. • For the best air diffusion, install the unit so that a side panel faces the wall. • Abestorm dehumidifiers are only intended for operation when the unit is upright and level with the feet on the ground.
  • Page 6 The continuous light will illuminate green and the display will show “CO”. · · To switch back to normal humidistat operation, use the arrow keys to move the setpoint above 36%. 4. Manual Drain Button · If you need to store or move your dehumidifier, press the “Drain” button to remove water from the integral pump’s reservoir.
  • Page 8 · The Abestorm Guardian SNS100 has an integrated condensate pump. During normal operation, the Guardian SNS100 will automatically drain as required. · If you would like to store or move your unit, press the drain button to drain water from the pump reservoir.
  • Page 11: Removing The Pump

    Removing the Pump 1. Remove the 9 screws on the side panel and set panel aside. 2. Remove the screw holding the pump in place. 3. Undo the 3 pump electrical quick connects and 1 drain quick connect. 4. Insert a flat head screwdriver into the notch on the side of the pump.
  • Page 12 Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. Both the inlet/return grille and the supply grille are designed for 10” flex ducting.
  • Page 13 Symptom Cause Solution Verify that both ends of the power cord are Poor Connection plugged in. Display is Blank Power Outage Reset power. Clean the filter. Filter is Dirty No AirFlow Air Inlet or Outlet is Blocked. Clear the blockage. Check to ensure that the sensor wire is Humidity Sensor or connected at both ends, if no issues are...
  • Page 14 Abestorm MERV-10...
  • Page 15 Return Authorization (RA number). Once an RA has been issued, customers should bring the unit to a certified repair center. Abestorm will arrange the shipping to bring the unit back to the Abestorm warehouse (at the expense of the customers) if customers are not available.
  • Page 16 Any dishonesty or fraud in connection with Abestorm warranty thoroughly voids all warranty policies. Abestorm expressly reserves the right to pursue legal action in the event of dishonesty, fraud, or attempted fraud.