Download Print this page

Lux Products LUXPRO PSD022B Installation And Operating Instructions page 2

Battery powered, non-programmable digital heat & cool thermostat

Advertisement

(PSD011B, PSD011Ba, PSD022B) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS
COOLING ONLY SYSTEMS
HEATING ONLY SYSTEMS
G
F
OPTIONAL
G
G
W1
W H
4
W1
W1
W2
OPTIONAL
W2
W2
*
022
*
022
Y2
Y2
Y1
Y1
JUMPER
JUMPER
RH
R
V
5
RH
RH
INSTALLED
INSTALLED
RC
RC
B/O
B/O
HEATING / COOLING SYSTEMS
HEATING / COOLING SYSTEMS
WITH ONE TRANSFORMER
WITH TWO TRANSFORMERS
G
F
G
G
W1
W H
4
W1
W1
W2
OPTIONAL
W2
W2
*
022
*
022
Y2
OPTIONAL
Y2
Y2
Y1
Y C*
6
PROVIDED
Y1
Y1
JUMPER
JUMPER
R
RH
RC
V
5
REMOVED
RH
RH
INSTALLED
RC
RC
B/O
B/O
TYPICAL SINGLE STAGE HEAT PUMP WIRING
G
F
G
"CUSTOMER SUPPLIED"
JUMPER
ADDED
W1
W2
*
022
Y2
Y
C* 6
Y1
JUMPER
R
RC
RH
V
5
RH
INSTALLED
RC
O
B
OPTIONAL
B/O
(PSD011B,PSD011Ba, PSD022B) FRANÇAIS – IDENTIFICATION DES FILS ET SCHÉMAS DE CÂBLAGE
SYSTÈMES DE
CHAUFFAGE SEULEMENT
REFROIDISSEMENT SEULEMENT
G
F
OPTIONNEL
G
G
W1
W H
4
W1
W1
W2
OPTIONNEL
W2
W2
*
022
*
022
Y2
Y2
Y1
Y1
CAVALIER
CAVALIER
RH
R
V
5
RH
INSTALLÉ
RH
INSTALLÉ
RC
RC
B/O
B/O
SYSTÈME DE CHAUFFAGE /
SYSTÈME DE CHAUFFAGE /
REFROIDISSEMENT
REFROIDISSEMENT
AVEC UN SEUL TRANSFORMATEUR
AVEC DEUX TRANSFORMATEURS
G
F
G
G
W1
W H
4
W1
W1
W2
OPTIONNEL
W2
W2
*
022
*
022
Y2
OPTIONNEL
Y2
Y2
Y1
Y C*
6
Y1
CAVALIER
Y1
FOURNI
CAVALIER
R
RH
RC
V
5
RH
RETIRÉ
RH
INSTALLÉ
RC
RC
B/O
B/O
FILS DE POMPE À CHALEUR À UN ÉTAGE TYPIQUE
G
F
G
CAVALIER AJOUTÉ
« FOURNI PAR LE CLIENT »
W1
W2
*
022
Y2
Y
C* 6
Y1
CAVALIER
R
RC
RH
V
5
RH
INSTALLÉ
RC
O
B
OPTIONNEL
B/O
(PSD011B, PSD011Ba, PSD022B) ESPAÑOL – IDENTIFICACION DE CABLES Y DIAGRAMAS DE CABLEADO
SISTEMAS EXCLUSIVOS
DE CALEFACCIÓN
G
F
OPCIONAL
G
W1
W H
4
W1
W2
OPCIONAL
W2
*
022
*
022
Y2
Y1
PUENTE
RH
R
V
5
PUENTE
RH
INSTALADO
INSTALADO
RC
B/O
SISTEMAS DE CALEFACCIÓN/ENFRIAMIENTO
SISTEMAS DE CALEFACCIÓN/ENFRIAMIENTO
CON UN TRANSFORMADOR
G
F
G
W1
W H
4
W1
W2
OPCIONAL
W2
*
022
*
022
Y2
OPCIONAL
Y2
Y1
Y C*
6
Y1
PUENTE
PROPORCIONADO
PUENTE
R
RH
RC
V
5
RETIRADO
RH
INSTALADO
RC
B/O
CABLES DE UNA BOMBA DE CALOR DE UNA SOLA FASE TÍPICA
G
F
G
PUENTE
"PROVISTO POR EL CLIENTE"
INCLUIDO
W1
W2
*
022
Y2
Y
C* 6
Y1
PUENTE
V
5
R
RC
RH
RH
INSTALADO
RC
O
B
OPCIONAL
B/O
G
F
B/O
Y2
OPTIONAL
Y1
C* 6
RC
R
V 5
B/O
G
F
W1
W H
4
W2
OPTIONAL
Y2
OPTIONAL
Y1
Y C*
6
RH
R
+
RC
R
V 5
SYSTEM
B/O
022*
(PSD022B)
ONLY
SYSTÈMES DE
G
F
Y2
OPTIONNEL
Y1
C* 6
RC
R
V 5
G
F
W1
W H
4
W2
OPTIONNEL
Y2
OPTIONNEL
Y1
Y C*
6
RH
R
RC
R
V 5
B/O
022*
(PSD022B)
SEULEMENT
SISTEMAS EXCLUSIVOS
DE ENFRIAMIENTO
G
F
G
W1
W2
Y2
OPCIONAL
Y2
Y1
C* 6
Y1
RH
RC
R
V 5
RC
B/O
CON DOS TRANSFORMADORES
G
F
G
W1
W H
4
W1
W2
OPCIONAL
W2
Y2
OPCIONAL
Y2
Y1
Y C*
6
Y1
RH
R
+
RH
RC
R
V 5
SISTEMA
RC
B/O
022*
SÓLO
(PSD022B)
TYPICAL 24 VOLT
HEATING ONLY SYSTEMS
Jumper INSTALLED
*
022
RC RH
Y1 Y2 W2 W1 G
System Common
-
+
STAGE-2
STAGE-1
SYSTEM
*
BLOWER
022
XFMR
FAN
HEATER
TYPICAL 24 VOLT
COOLING ONLY SYSTEMS
Jumper INSTALLED
*
022
RC RH
Y1 Y2 W2 W1 G
System Common
-
STAGE-1
STAGE-2
*
022
BLOWER
XFMR
FAN
A/C COMPRESSOR
TYPICAL 24 VOLT, HEATING & COOLING SYSTEMS
WITH ONE TRANSFORMER
*
022
Jumper INSTALLED
RC RH
Y1 Y2 W2 W1 G
System Common
-
+
STAGE-1
STAGE-2
STAGE-2
STAGE-1
SYSTEM
*
*
BLOWER
022
022
XFMR
FAN
A/C COMPRESSOR
HEATER
SYSTÈMES DE CHAUFFAGE
TYPIQUE DE 24 VOLTS SEULEMENT
Cavalier INSTALLÉ
*
022
B/O
RC RH
Y1 Y2 W2 W1 G
Système commun
-
+
ÉTAGE-2
ÉTAGE-1
*
022
VENTILATEUR
SYSTÈME
XFMR
SOUFFLANT
RADIATEUR
SYSTÈMES DE REFROIDISSEMENT
TYPIQUE DE 24 VOLTS SEULEMENT
Cavalier INSTALLÉ
*
022
B/O
RC RH
Y1 Y2 W2 W1 G
Système commun
-
+
ÉTAGE-1
ÉTAGE-2
SYSTÈME
*
VENTILATEUR
022
XFMR
SOUFFLANT
COMPRESSEUR
DE CLIMATISATION
SYSTÈMES DE CHAUFFAGE ET DE REFROIDISSEMENT
TYPIQUES DE 24 VOLTS AVEC UN TRANSFORMATEUR
*
022
Cavalier INSTALLÉ
RC RH
Y1 Y2 W2 W1 G
Système commun
-
+
ÉTAGE-1
ÉTAGE-2
ÉTAGE-2
ÉTAGE-1
*
SYSTÈME
*
022
VENTILATEUR
022
XFMR
SOUFFLANT
RADIATEUR
COMPRESSEUR
DE CLIMATISATION
SISTEMAS TÍPICOS EXCLUSIVOS
DE CALEFACCIÓN DE 24 VOLTIOS
Puente INSTALADO
*
022
B/O
RC RH
Y1 Y2 W2 W1 G
Sistema Común
-
+
DOS FASES UNA FASE
*
SISTEMA
022
VENTILADOR
XFMR
CALENTADOR
SISTEMAS TÍPICOS EXCLUSIVOS
DE ENFRIAMIENTO DE 24 VOLTIOS
Puente INSTALADO
*
022
B/O
RC RH
Y1 Y2 W2 W1 G
Sistema Común
-
UNA FASE DOS FASES
*
022
VENTILADOR
XFMR
COMPRESOR DE
AIRE ACONDICIONADO
SISTEMAS TÍPICOS DE CALEFACCIÓN Y ENFRIAMIENTO
DE 24 VOLTIOS CON UN TRANSFORMADOR
Puente INSTALADO
*
022
B/O
RC RH
Y1 Y2 W2 W1 G
Sistema Común
-
+
UNA FASE DOS FASES
DOS FASES UNA FASE
*
*
SISTEMA
022
022
VENTILADOR
XFMR
COMPRESOR DE
CALENTADOR
AIRE ACONDICIONADO
022*
TYPICAL 24 VOLT, HEATING & COOLING SYSTEMS
(PSD022B)
WITH TWO TRANSFORMERS
ONLY
Provided Jumper REMOVED
B/O
RC RH
Common #1
Common #2
-
-
+
+
STAGE-1
COOL
HEAT
XFMR
XFMR
A/C COMPRESSOR
Chassis Ground
022*
(PSD022B)
TYPICAL 24 VOLT, SINGLE-STAGE
ONLY
Jumper INSTALLED
B/O
RC RH
-
+
REVERSING
SYSTEM
VALVE
XFMR
022*
WIRING DIAGRAM NOTES:
(PSD022B)
1. The BOLD lines are what you should be connecting to the terminals on this new
ONLY
thermostat.
2. The DASHED lines are optional depending upon your system type.
3. In many cases, the thin lines shown as "SYSTEM COMMON" will not be visible at
the thermostat location, they are located with your heating and cooling equipment.
4. For Heat Pumps, use the "B" or "O" wire, NOT BOTH. Typically neither are used
in a conventional system.
5. If "Y" and "C" wires are both present, then "C" is a common wire.
6. If you have a "B" wire in your system which is used as a common wire,
connecting it to the "B/O" terminal on this thermostat may damage your system
and/or the thermostat.
022*
SYSTÈMES DE CHAUFFAGE ET DE REFROIDISSEMENT
(PSD022B)
TYPIQUES DE 24 VOLTS AVEC DEUX TRANSFORMATEURS
SEULEMENT
Cavalier fourni RETIRÉ
B/O
RC RH
Commun n° 1
Commun n° 2
-
-
+
+
ÉTAGE-1
REFROIDISSEMENT
CHAUFFAGE
XFMR
XFMR
DE CLIMATISATION
022*
Châssis mis à la terre
(PSD022B)
SYSTÈMES DE POMPE À CHALEUR
SEULEMENT
TYPIQUES À UN ÉTAGE, 24 VOLTS
Cavalier INSTALLÉ
B/O
RC RH
-
+
COMPRESSEUR
ROBINET
SYSTÈME
DE POMPE À CHALEUR
INVERSEUR
XFMR
022*
REMARQUES AU SUJET DES SCHÉMAS DE BRANCHEMENT :
(PSD022B)
1. Les lignes en GRAS représentent les fils que vous devriez connecter aux bornes de
SEULEMENT
ce nouveau thermostat.
2. Les traits TIRÉS sont optionnels d'après le type de votre système.
3. Dans de nombreux cas, les lignes minces marquées « SYSTÈME COMMUN » ne
seront pas visibles où le thermostat se trouve, car elles se trouvent avec les
appareils de chauffage et de climatisation.
4. Pour les pompes à chaleur, utilisez le fil « B » ou le fil « O », MAIS PAS LES DEUX.
Ceux-ci ne sont habituellement pas utilisés pour les systèmes traditionnels.
5. Si « Y » et « C » sont tous les deux présents, alors « C » est un fil commun.
6. Si un fil « B » de votre système est un fil commun, le connecter à la borne
« B/O » du thermostat pourrait endommager votre système et/ou le thermostat.
022*
SISTEMAS TÍPICOS DE CALEFACCIÓN Y ENFRIAMIENTO
DE 24 VOLTIOS CON DOS TRANSFORMADORES
SÓLO
(PSD022B)
Puente Proporcionado RETIRADO
B/O
RC RH
Común #1
Común #2
-
-
+
+
ENFRIAMIENTO
CALEFACCIÓN
XFMR
XFMR
Tierra del chasis
022*
SÓLO
SISTEMAS TÍPICOS DE BOMBAS DE CALOR
DE UNA SOLA FASE DE 24 VOLTIOS
(PSD022B)
Puente INSTALADO
B/O
RC RH
-
+
COMPRESOR DE
VÁLVULA
SISTEMA
BOMBA DE CALOR
DE INVERSIÓN
XFMR
DE UNA SOLA FASE
022*
COMENTARIOS SOBRE LOS DIAGRAMAS DE CABLEADO:
1. Las líneas RESALTADAS son las que debe conectar a los terminales de este
SÓLO
nuevo termostato.
(PSD022B)
2. Las líneas ENTRECORTADAS son opcionales de acuerdo con su tipo de sistema.
3. En muchos casos, las líneas delgadas, que se indican como "SISTEMA COMUN",
no se pueden ver en el termostato porque se encuentran en su equipo de
calefacción y refrigeración.
4. Para las bombas de calor, use el alambre "B" u "O", NO AMBOS. Generalmente
no se utiliza ninguno en un sistema convencional.
5. Si hay un alambre "Y" y un alambre "C", el común será el alambre "C".
6. Si un alambre "B" en su sistema se utiliza como alambre común, entonces
conectarlo al terminal "B/O" del terminal del termostato puede causar daños a su
sistema y/o al termostato.
022*
(PSD022B)
ONLY
*
022
Y1 Y2 W2 W1 G
STAGE-2
STAGE-2
STAGE-1
*
*
BLOWER
022
022
FAN
HEATER
022*
(PSD022B)
ONLY
HEAT PUMP SYSTEMS
"Customer Supplied"
*
022
Jumper ADDED
Y1 Y2 W2 W1 G
System Common
SINGLE STAGE
BLOWER
HEAT PUMP
FAN
COMPRESSOR
022*
(PSD022B)
SEULEMENT
*
022
Y1 Y2 W2 W1 G
ÉTAGE-2
ÉTAGE-2
ÉTAGE-1
*
*
VENTILATEUR
022
022
SOUFFLANT
RADIATEUR
COMPRESSEUR
022*
(PSD022B)
SEULEMENT
*
022
Y1 Y2 W2 W1 G
Système commun
VENTILATEUR
SOUFFLANT
À UN ÉTAGE
022*
SÓLO
(PSD022B)
*
022
Y1 Y2 W2 W1 G
UNA FASE DOS FASES
DOS FASES UNA FASE
*
*
022
022
VENTILADOR
COMPRESOR DE
CALENTADOR
AIRE ACONDICIONADO
022*
SÓLO
(PSD022B)
*
022
Y1 Y2 W2 W1 G
Sistema Común
VENTILADOR

Advertisement

loading

This manual is also suitable for: