MIG WELDING SET-UP
AND OPERATION
SET-UP FOR MIG WELDING
Installing the MIG Welding Gun
• Open the side door of the Welder and loosen the
Torch Tensioner Wing Screw located on the side of
the brass, hex shaped member of the Drive Motor
Assembly (FIG 2).
• Plug the Brass Body End of the Welding Gun line into
the designated socket (FIG 3).
IMPORTANT NOTE: The Brass Body End must be
fully seated against the base of the drive assembly
socket or gas may either leak or not be able to pass
through the connections to the end of the Welding
Gun (FIG 4).
• Tighten the Torch Tensioner Wing Screw finger tight
(FIG 3).
• Connect the Male Metal Plug to the Female Cannon
Plug connection on the front of the Welder (FIG 4).
• Set the Selector Switch [A] located on the Front
Panel to the MIG Position (FIG 1).
8
FIG. 2
FIG. 3
FIG. 4