Model
Item
Capacity
Total
SHF
Input
Outdoor unit
Power supply (V, phase, Hz)
Electrical
Input
circuit
Comp. current (208/230V)
Fan motor current (208/230V)
Condensing pressure
Suction pressure
Discharge temperature
Refrigerant
Condensing temperature
circuit
Suction temperature
Comp. shell bottom temp.
Ref. pipe length
[Total pipe length for multi-system]
Refrigerant charge (R410A)
Intake air temperature
Outdoor
unit
Fan speed
Airflow
Unit
Btu / h
—
kW
kW
A
A
PSIG
PSIG
˚F
˚F
˚F
˚F
ft.
—
DB
˚F
WB
˚F
rpm
CFM
24
MXZ-3A30NA MXZ-3A30NA -
Cooling
28,400
–
3.25
MXZ-3A30NA MXZ-3A30NA -
208/230, 1, 60
3.197
15.45/13.97
0.43/0.39
506
136
190
132
48
146
25 [75]
7lb.11oz.
95
—
520
1,365
1
Heating
28,600
–
2.18
1
2.127
10.15/9.18
0.43/0.39
330
96
150
100
30
125
47
43
600
1,605