Advertisement

Quick Links

INSTALLATION MANUAL
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
This product contains Fluorinated Greenhouse Gases. (R410A)
WALL MOUNTED
Original instruction
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
P/NO : MFL67855409
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG MS24AWV

  • Page 1 This product contains Fluorinated Greenhouse Gases. (R410A) WALL MOUNTED Original instruction [Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands [Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA www.lg.com...
  • Page 2 TIPS FOR SAVING ENERGY TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: •...
  • Page 3: Important Safety Instructions

    SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid danger- ous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ig- nored CAUTION It can result in minor injury or product damage when the direc-...
  • Page 4 SAFETY PRECAUTIONS Installation • Don’t use a power cord, a plug or a loose socket which is damaged. - Otherwise, it may cause a fire or electrical shock. • For electrical work, contact the dealer, seller, a qualified elec- trician, or an Authorized Service Center. - Do not disassemble or repair the product.
  • Page 5 TIPS FOR SAVING ENERGY • Do not install the product on a defective installation stand. - It may cause injury, accident, or damage to the product. • Be sure the installation area does not deteriorate with age. - If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal in- jury.
  • Page 6 TIPS FOR SAVING ENERGY • Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. - It may cause a problem for your neighbors. • Use two or more people to lift and transport the product. - Avoid personal injury.
  • Page 7: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS TIPS FOR SAVING EN- INSTALLATION Select the best Location ERGY Fixing Installation Plate Drill a Hole in the Wall IMPORTANT SAFETY IN- Flaring Work STRUCTIONS Connecting the Piping Connecting the Cables Checking the Drainage INSTALLATION PARTS Installation of filters Test Running...
  • Page 8: Installation Parts

    INSTALLATION PARTS INSTALLATION PARTS Name Quantity Shape Installation plate 1 EA The feature can be changed according a type of model. Type "A" screw 5 EA Type "B" screw 2 EA Type "C" screw 2 EA Remote control 1 EA holder Screws for fixing panels are attached to decoration panel.
  • Page 9: Installation Map

    INSTALLATION MAP INSTALLATION MAP Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters Saddle and pour water into the heat...
  • Page 10: Installation

    INSTALLATION INSTALLATION Installation Plate Select the best Location - There should not be any heat or steam near the unit. Type "A" Screws - Select a place where there are no obstacles around of the unit. Chassis - Make sure that condensation drainage can Hook be conveniently routed away.
  • Page 11: Drill A Hole In The Wall

    INSTALLATION Drill a Hole in the Wall Burrs removal Completely remove all burrs from the cut - Drill the piping hole with a ø65mm hole core cross section of pipe/tube. drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the While removing burrs put the end of the outdoor side.
  • Page 12: Connecting The Piping

    INSTALLATION Unlock the tubing holder from the chassis Handle and mount between the chassis and instal- lation plate in order to separate the bottom side of the indoor unit from the wall. Yoke Cone Copper pipe Clamp handle Red arrow mark Tubing Holder Check Compare the flared work with the figure...
  • Page 13 INSTALLATION Bad case Pull back the tubing holder. Remove pipe port cover and positioning - Following bending case from right to left di- the tubing rectly may cause damage to the tubing. Indoor unit back side view Pipe Port Left Right Tubing holder Backwards...
  • Page 14 INSTALLATION Right side piping When needed to extend the drain hose of indoor unit, assembly the drain pipe as shown on the drawing Tape Drain pipe Connecting cable Drain hose Indoor unit drain hose Connecting pipe Vinyl tape(narrow) Adhesive CAUTION Wrap the insulation material If the drain hose is routed inside the room insulate the hose with an insulation mate-...
  • Page 15: Connecting The Cables

    INSTALLATION Finishing the indoor unit Connecting the Cables installation Indoor unit Mount the tubing holder in the original Connect the cable to the indoor unit by con- positon. necting the wires to the terminals on the con- Ensure that the hooks are properly seated trol board individually according to the outdoor on the installation plate by moving it left unit connection.
  • Page 16: Checking The Drainage

    INSTALLATION Checking the Drainage Do not make drain piping like the follow- ing. To check the drainage. Pour a glass of water on the evaporator. Do not raise Ensure the water flows through the drain hose of the indoor unit without any leak- age and goes out the drain exit.
  • Page 17: Installation Of Filters

    INSTALLATION Installation of filters Test Running Pull out the [Allergy free filter + Triple Fil- - Check that all tubing and wiring are properly ter] from the separately packed plastic bag. connected. Detach the two nitto tapes from the filter. - Check that the gas and liquid side service valves are fully open.

This manual is also suitable for: