This product contains Fluorinated Greenhouse Gases. (R410A) WALL MOUNTED Original instruction [Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands [Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA For more information, Refer to the CD or LG Web site (www.lg.com).
Page 2
TIPS FOR SAVING ENERGY TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: •...
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLI- ANCE. Always comply with the following precautions to avoid danger- ous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ig- nored CAUTION It can result in minor injury or product damage when the direc-...
Page 4
IMPORTANT SAFETY INSTRUCTIONS - Do not disassemble or repair the product. There is risk of fire or electric shock. • Always ground the product. - There is risk of fire or electric shock. • Install the panel and the cover of control box securely. - There is risk of fire or electric shock.
Page 5
IMPORTANT SAFETY INSTRUCTIONS - There is the risk of death, injury, fire or explosion. Operation • Do not store or use flammable gas or combustibles near the product. - There is risk of fire or failure of product. CAUTION Installation •...
Page 6
IMPORTANT SAFETY INSTRUCTIONS • For R410A model, use piping, flare nut and tools which is specified for R410A refrigerant. - Using of (R22) piping, flare nut and tools may cause abnor- mally high pressure in the refrigerant cycle (piping), and pos- sibly result in explosion and injury.
TABLE OF CONTENTS TABLE OF CONTENTS TIPS FOR SAVING EN- INSTALLATION MAP ERGY INSTALLATION IMPORTANT SAFETY IN- Select the best Location STRUCTIONS Fixing Installation Plate Drill a Hole in the Wall Flaring Work INSTALLATION PARTS Connecting the Piping Checking the Drainage Test Running INSTALLATION TOOLS...
INSTALLATION PARTS INSTALLATION PARTS Name Quantity Shape Installation plate 1 EA The feature can be changed according to type of model. Type "A" screw 5 EA Type "B" screw 2 EA Type "C" screw 2 EA Remote control 1 EA holder Screws for fixing panels are attached to decoration panel.
INSTALLATION MAP INSTALLATION MAP Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters Saddle and pour water into the heat...
INSTALLATION INSTALLATION Select the best Location Fixing Installation Plate - There should not be any heat or steam near The wall you select should be strong and solid the unit. enough to prevent vibration - Select a place where there are no obstacles Mount the installation plate on the wall around of the unit.
INSTALLATION Drill a Hole in the Wall Burrs removal Completely remove all burrs from the cut - Drill the piping hole with a ø65mm hole core cross section of pipe/tube. drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the While removing burrs put the end of the outdoor side.
INSTALLATION Pull back the tubing holder. Handle Remove pipe port cover and positioning the tubing Yoke Indoor unit back side view Cone Copper pipe Pipe Port Clamp handle Red arrow mark Left Tubing holder Check Right Compare the flared work with the figure Backwards If a flared section is defective, cut it off * The feature can be changed according to...
Page 13
INSTALLATION Bad case Installation of Indoor Unit - Following bending case from right to left di- Hook the indoor unit onto the upper por- rectly may cause damage to the tubing. tion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving...
Page 14
INSTALLATION <Right side piping> CAUTION If the drain hose is routed inside the room insulate the hose with an insulation mate- rial* so that dripping from sweating conden- sation) will not damage furniture or floors. * Foamed polyethylene or equivalent is recommended.
Page 15
INSTALLATION Wrap the insulation material Finishing the indoor unit around the connecting portion. installation Overlap the connection pipe insulation ma- Mount the tubing holder in the original terial and the indoor unit pipe insulation positon. material. Bind them together with vinyl Ensure that the hooks are properly seated tape so that there may be no gap.
INSTALLATION Checking the Drainage Do not make drain piping like the follow- ing. To check the drainage. Pour a glass of water on the evaporator. Do not raise Ensure the water flows through the drain hose of the indoor unit without any leak- age and goes out the drain exit.
INSTALLATION Test Running - Check that all tubing and wiring are properly connected. - Check that the gas and liquid side service valves are fully open. Prepare remote controller Remove the battery cover by pulling it ac- cording to the arrow direction. Insert new batteries making sure that the (+) and (–) of battery are installed correctly.