be more accurate if the camera calibration is configured.
Steps:
1. Check the checkbox of Camera Calibration to enable this function.
2. Select the calibration mode as Input Basic Data or Draw on Live View Video.
Input Basic Data: Input the mounting height, viewing angle, and horizon
ratio of the camera manually.
Draw on Live View Video: Click Draw Verification Line (Horizontal) /
(Vertical) to draw a horizontal/vertical line in the live view, and input the
actual length in Real Length field. With the drawn reference lines and their
real length, the camera can conclude other objects appear in the live view.
3. Click the Horizontal Verify
horizontal / vertical line on the live video, and click the Start Verifying
button to calculate the line length. Compare the calculated line length to the
actual length to verify the calibration information you set.
Note:
If the live view is stopped, the camera calibration is invalid.