Troubleshooting - Greenlee 2562 Instruction Manual

Greenlee 2562 battery chargers: user guide
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting (Battery)
PROBLEM
No LEDS light up.
Charge Indicator disagrees
with charger.
Battery feels warm.
Battery feels hot!
Tool runs slow.
Battery does not hold a charge.
Greenlee Textron / Subsidiary of Textron Inc.
Battery Charger
PROBABLE CAUSE
Battery is fully discharged.
Battery is damaged.
Charger has not completed the
last 20% of charge.
Battery has been topped-off too
many times without a full discharge.
Battery has been damaged.
Normal usage or charging.
Battery was shorted.
Battery was very heavily used.
Crimper is out of calibration.
Crimper and battery are cold.
Battery is low.
Battery is worn out.
Battery is damaged.
Battery has not been used for several
days. (All batteries self-discharge.)
Battery is worn out.
Battery is damaged.
Charge battery.
Replace battery.
Leave in the charger.
Place into the charger and press
the recondition button on the charger.
Replace battery.
No action required.
Allow to cool and retry.
Allow to cool.
Send tool to authorized Greenlee
service center for calibration.
Allow unit to warm.
Charge battery.
Replace battery.
Replace battery.
Charge battery.
Replace battery.
Replace battery.
15
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
POSSIBLE REMEDY

Advertisement

Table of Contents
loading

This manual is also suitable for:

25632564

Table of Contents