UNISource Corporation DM-1150B Operation Manual page 4

Bench digital multimeter
Table of Contents

Advertisement

1. Power switch: turns the meter on or off
2. Auxiliary keys: SELECT, RANGE, SET, MAX/MIN, Timer/RS232/HOLD/2nd VIEW/ REL △
SELECT: Selects measurement mode
RANGE: Selects measurement range. The meter is default at auto range mode.
SET:
When the SET button is in operation, the RANGE button is used as a moving up button ( ), the 2nd VIEW
button as a moving down button ( ), the MAX/MIN as a moving left button ( ), and REL △ as a moving
right ( ). In this case, the RANGE, 2nd VIEW, MAX/MIN and REL△ buttons' original functions are
disabled.
Press SET button for at least 2 seconds to start the backlight. Press this button again to turn off the backlight.
The backlight can auto off if this button is not engaged within 30 seconds.
MAX/MIN:
Presses this button to enter the dynamic record mode, with maximum record period of 36 hours.
In the dynamic record mode, the meter automatically records the maximum value (MAX), minimum value
(MIN), difference value (MAX-MIN) and calculate the average value (AVG) of all readings. Press this button
to cycle MAX, MIN, AVG, MAX-MIN on the secondary display.
Pressing this button for at least 2 seconds, the meter returns to auto range.
Timer/RS232:
TIME:
TIMER function is enabled only in the REL△ and M AX / M IN measuring mode.
Press TIMER key to start the secondary display for counting time. Press TIMER key again to turn off the
counting time display.
When the secondary display is display counting time, press key SELECT to enter Beeper setup for setting up
a timer for beeper. Then, press key REL△ ( ), MIX/MIN ( ), RANGE ( ), 2nd VIEW ( ) to input the
time. Next press key TIMER to validate the new time data. When the counting time exceeds the preset time,
the beeper sounds.
In the above two modes, press key HOLD to stop timer function and turn off secondary display, but the
preset time remains unchanged.
The time is display in the format of 8.88.88 on the secondary display. The max.counting time is 9.59.59
RS232:
Pressing this button for at least 2 seconds, the RS232 remote control is enabled for PC control and
communication with other instruments. The LCD display "RS232'
Auto power off function is disabled in this RS232 programmable mode.
Pressing this button for at least 2 seconds again to exits this mode and return to normal mode.
HOLD:
Pressing this button, the meter enters auto data hold mode and "A-H" is displayed on the LCD.
The data hold mode allows users to hold the displayed value while the analog bar graph shows the current
reading.
Pressing this button again, the meter enters Peak+ hold mode and a "PH+" appears on the LCD display.
Pressing this button again, the meter enters Peak- hold mode and a "PH-" appears on the LCD display.
Pressing this button for at least 2 seconds, the meter exits HOLD mode and return to normal mode.