record.
The meter is in auto range mode and will automatically select a most suitable range. To select a range
manually for the measurement, press RANGE button to select a proper range. There are six ranges to choose
from: 800.00Ω/8.0000kΩ/80.000kΩ/800.00kΩ/8.0000MΩ/80.000MΩ
Connect the black test lead to "COM" terminal and the read test lead to "VΩ Hz" terminal.
Touch the probes to the test points and read the display.
Measurement mode
Ω
Continuity mode
Press SELECT button to select " " range.
If the testing points resistance falls below 50Ω. The beeper will sound.
Hi resistance
This function is used to measure the resistance above 80MΩ.
Press SELECT button to select "HiΩ" range. The primary display will display "Hi".
A single range is 8000.0MΩ. If the testing points resistance falls below 10MΩ and above 8000.0MΩ, "OL"
will appears on the display.
4.7 Capacitance Measurement (CAP)
WANRNING: To avoid damage to the meter or the testing equipments disconnect circuit power and
discharge all high voltage capacitors before measuring capacitance. Use the DC function to confirm that the
capacitor is discharged.
NOTE:
Some capacitors have polarities. In measuring polarities capacitors, touch the red test lead to the positive
polarity and the black test lead to the negative polarity.
In measuring low capacitance, the resistance of the test leads may cause an error in the test results. To avoid
this error, first short the test leads, next press REL△ button. The primary display will be null and the
secondary display displays the resistance of test lead. Measure the to-be tested resistance and the result will
be displayed on the primary display.
Capacitor is capable of storing electric charge. When testing capacitance, only the value on a stable display is the
correct result.
Set the function to "
According to practical demands, press REL△, MAX/MIN and 2nd VIEW buttons to have relative
measuring or record.
The meter is in auto range mode and will automatically
select a most suitable range. To select a range manually for
the measurement, press RANGE button to select a proper
range. There are six ranges to choose from:
1.0000nF/10.000nF/100.00nF/1.0000μF/10.000μF/100.00μF
Connect the black test lead to "COM" terminal and the red
test lead to "VΩ Hz" terminal.
Touch the probes to the test points and read the display.
Find Quality Products Online at:
Primary display
Secondary display
Ω/kΩ/MΩ
MAX/MIN, REL△ parameters
" position.