Table 8. Capacitance
Range
1nF
10nF
100nF
1μF
10μF
100μF
Table 9. Diode
Range
3.0000V
Table 10. Square Wave Output
Voltage amplitude
Frequency
Duty cycle
Table 11. Temperature
Range
-50℃~1300℃
-58℉~2372℉
6.2 General Specifications
Max.voltage between terminal and ground: 1000V RMS
Continuity beeper: Approx.3kHz
Display: dual display 80000, update 4 time/Sec.
Bar graph: 23 segments, update 40 time/Sec.
Electromagnetic compatibility:
For all ranges and functions (except capacitance), in a RF field of 1V/m, total accuracy=specified
accuracy+5% of range.
In a RF field, the capacitance has no specified range.
or all ranges and functions, in a RF field above 1V/m, there is no specified range.
Safety/Compliance: IEC 61010 CAT II 1000V, and CAT III 600V
Input voltage: AC110V/220V selectable, 50/60Hz
Operating environment: temperature 0℃~50℃, altitude below 2000m
Storage environment: temperature -20℃~60℃, altitude below 5000m
Relative humidity: ≤75%, at 0℃~40℃; ≤45%, at 40℃~50℃
Dimension: 260x220x82mm
Weight: Approx.1.4KG
Accessories:
Manual: 1pcs
Test lead: 1pcs
K type thermocouple: 1pcs
RS232 package: 1set
Find Quality Products Online at:
Resolution
1pF
10pF
100pF
1nF
10nF
100nF
Accuracy
Resolution
±(3.0% rdg+5)
0.0001V
Accuracy
Resolution
0.1℃
±(1.5% rdg+10)
0.1℉
GlobalTestSupply
www.
Accuracy
±(5.0% rdg+50)
±(2.5% rdg+50)
Remarks
Diode positive voltage drop
Overload protection: 250V RMS
Description
Approx.3V
0.5Hz~5000Hz
1%~99%
Remarks
K type thermocouple
Overload protection: 250V RMS
.com
- 18 -
Remarks
Overload protection: 250V RMS