Domestic water heating
Storage function
Automatic storage set point [b-02]?
Yes
Automatic daily pre-programmed?
Yes
Automatic storage
function (default)
Yes
Sufficient hot water?
No
Active daily day
storage [1-02]
Choose start time
[1-03]
Automatic daily
day storage
Automatic daily night storage
[1-00] and [1-01]
Push p button
p icon will appear, domestic hot
water will be produced at next
scheduled action.
When making domestic hot water,
w icon will be blinking (1 second
interval)
Stop
Stop and restart
Enable/disable
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system
4PW54465-1C
Yes Normal domestic hot water
Yes
No
Storage
operation?
Reheat function
Reheat minimum
temperature [b-00]
Reheat maximum
No
temperature [b-01]
Storage set
point [b-03]
Push w button
No
Schedule storage
Reheat enabled,
w icon continuous
function
visible
Schedule domestic
Push w button (*)
hot water
Custom made
Reheat disabled
domestic hot water
w icon not visible
schedule
(*) It is not possible to
see when actual
domestic hot water is
made. If you want to
disable reheat
function and at the
same time domestic
hot water is being
produced in reheat
operation, you have to
push 2 times the w
button; 1 time to stop
current reheat
domestic hot water
operation and 1 time
to stop reheat enable.
Push w button
No
operation?
Yes
Disinfection function
[4-00] (default)
Disinfection set point
[5-00]
Disinfection retention
time [5-01]
Day selection [4-01]
Hour selection [4-02]
Disinfection function
will operate
depending on
settings request
w icon will start
blinking with 0.5
second intervals
Push w button
Current disinfection
operation will stop,
but restart next
scheduled action.
w icon will return to
previous state.
Current domestic hot water operation will
stop, but restart next scheduled action.
w icon will return to previous state.
Forced operation
Automatic?
No
Manual storage
function
Automatic
storage set point
[b-02]?
Yes
Push w button
for 5 seconds
Domestic hot
water production
will start
immediately
w icon will start
blinking with 1
second intervals
Push w button
Domestic hot
water production
will stop.
w icon will return
to previous state.
Installation manual
No
Storage set
point [b-03]
38