Mains Electricity Connection

Warning! This appliance must be earthed
We recommend that the appliance is connected by a qualified
electrician, who is a member of the N.I.C.E.I.C. and who will comply
with the I.E.T. and local regulations.
This appliance is intended to be connected to fixed wiring and is
not suitable for connection to a 13A plug or 13A supply.
This appliance is intended to be connected to fixed wiring by a
double pole switch, having a contact separation of at least 3mm in
all poles. The switch must be positioned no further than 2m from the
appliance.
This appliance is supplied with a 3 core mains cable; the wires are in
accordance with the following code:
Green and Yellow = Earth
Blue = Neutral
Brown = Live
Please note:
The mains cable r and must be of equivalent or better rating (i.e.
0.5mm2, HO3VV-F).
The current rating of the fuse or circuit breaker protecting this
appliance should be marked on the socket outlet (3A).
Assembly and electrical connection should be carried out by
specialised personnel.
When installing this product we recommend you seek the help of