If you connect a ground cable to the ground point on the enclosure shell in a scenario with a
neutral wire, you are recommended to use a four-core outdoor copper-core cable with a cross-
sectional area of 16 mm
and a four-core outdoor copper cable with a cross-sectional area of 25 mm
power cable for the SUN2000-36KTL.
If you connect a ground cable to the ground point in the maintenance compartment in a
scenario with a neutral wire, you are recommended to use a five-core outdoor copper-core
cable with a cross-sectional area of 16 mm
29.9KTL/33KTL-A and a five-core outdoor copper cable with a cross-sectional area of 25 mm
as the AC output power cable for the SUN2000-36KTL.
For more details about cable specifications, see the SUN2000-(29.9KTL, 33KTL-A, 36KTL,
42KTL) User Manual.
The AC OUTPUT 1 connector supports the cable with an outer diameter of 18 mm to 44 mm.
1. Remove the two security torx screws from the
maintenance compartment door using a security
torx wrench. (Set the two screws aside. Use the
idle ground screw on the enclosure shell as the
standby screw, and the idle floating nut on the
enclosure as the standby floating nut.)
3. Remove the AC terminal cover.
2
as the AC output power cable for the SUN2000-29.9KTL/33KTL-A
2
as the AC output power cable for the SUN2000-
6
2
as the AC output
2. Open the maintenance
compartment door and adjust the
support bar. (The support bar is
bound to the enclosure base.)
2