Zigbee heating thermostat

Advertisement

Quick Links

Zigbee Heating Thermostat SR-ZG9092A
Important: Read All Instructions Prior to Installation
Function introduction
LED Display
TIME/SHIFT button, to set
time schedule of the
device quickly and move
the cursor
Mode button, to switch
operation modes and quit
10 mm 10 mm
31 mm
Floor temp sensor
Revised 07.02.2022
Home Interface
Function button, to
confirm, save setting
Move up and move down
F
buttons
Front side
80 mm
59 mm
SR-ZG9092A
NTC
L
L N N
AC Power input
Output
Back side
1. Product Data
Radio Frequency
2.4GHz
Input Voltage
EU: AC200-240V, 50/60Hz
Output Voltage
EU: AC200-240V
Max Load
3680W @ 230V (resistive load)
Max Current
16A
Power Consumption
<2W
Ambient Temperature
0°C to 40°C (during operation)
Set Temperature Range
0°C to 40°C
Hysteresis
0.5°C to 2°C (default 0.5°C)
1. NTC/10K B(25/50℃)=3950 (default)
2. NTC/15K B(25/50℃)=3950
Floor sensor type
3. NTC/50K B(25/50℃)=3950
4. NTC/100K B(25/50℃)=3950
5. NTC/12K B(25/50℃)=3950
Control Mode
AWAY, AUTO, MANUAL, DRYING, OFF
Control type means which temperature sensor the device refers to
when it adjust temperature.
Room sensor: adjust temperature refers to room temperature
(factory default type).
Control Type
Floor sensor: adjust temperature refers to floor temperature.
Room+Floor sensor: adjust temperature refers to both room
temperature and floor temperature.
Current ≤ 13A - 1.5mm² wire
Wiring Requirement
Current > 13A to 16A - 2.5mm² wire
IP Rating
IP21
Control Pollution Degree (Method D)
pollution degree 2
Rated Impulse Voltage (Method D)
4kV
Relative Humidity
8% to 80%
Dimensions
80x80x52mm
CE,
LVD: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1
EMC & RF: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,
EN 60730-1:2016+A1:2019, EN 60730-2-
Approvals
19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-
1V2.2.3, ETSI EN301 489-3V2.1.1
ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1
RED certificate: 2014/53/EU
• The Zigbee HVAC controller is a wireless thermostat for heating system, which complies to Zigbee 3.0
wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and
locally or through remote controlled through Zigbee gateway controller.
• All setup is performed via supported IEEE 802.15.4-based control platforms and other Zigbee3.0 compatible
control systems. Appropriate gateway control software allows for adjustment of control mode, control type,
schedule etc.
• Sensors: Air temperature
• THERMOSTAT MODE: OFF, HEAT, ENERGY HEAT, AWAY, DRY
• Measurement range: –10°C to +60°C
• Accuracy: ±0.1°C
• WARNING: Electrical power must be switched off during installation

Advertisement

loading
Need help?

Need help?

Do you have a question about the SR-ZG9092A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sunricher SR-ZG9092A

  • Page 1 1. Product Data Zigbee Heating Thermostat SR-ZG9092A Revised 07.02.2022 Radio Frequency 2.4GHz Input Voltage EU: AC200-240V, 50/60Hz Output Voltage EU: AC200-240V Important: Read All Instructions Prior to Installation Max Load 3680W @ 230V (resistive load) Function introduction Max Current Power Consumption <2W...
  • Page 2 2.Home Interface AWAY Mode: this mode means there is no person at home, to keep a certain indoor temperature, the user can set the deadline of away, it also can be considered as anti-freezing function, the recommended setting 2.1 Home Interface temperature is 4-10 degrees.
  • Page 3: Monitor Set

    Max floor temp (27°C by default) 7:30,24℃ ~ 12:00,20℃ This function is similar to the function of “Internal Over Heat Protection” 18:00,16℃ ~ 22:30,18℃ described in chapter 4.9. When the control type is configured as “Room+Floor Saturday~Sunday sensor”, this function will be valid: 7:30,24℃...
  • Page 4: Other Set

    4.9 OTHER SET Display Temp type (Home Temp by default) Select OTHER SET on Home Interface to enter into OTHER SET interface as follow: This parameter defines which sensor temperature will be displayed on Home page. Floor Temp: floor temperature (external sensor). Short press button to select the item would like to modify, then short Home Temp: indoor air temperature.
  • Page 5 Hardware version 1 read-only Endpoint Application Profile ManufacturerName string, 0(0x00) 0x0000(ZDP) ZigBee Device Object (ZDO) – standard management features 0x0004 read-only “Sunricher” 1(0x01) 0x0104(HA) Device ID is 0x0301(Thermostat ). string, ModelIdentifier 2(0x02) 0x0104(HA) Device ID is 0x0007(OTA). 0x0005 read-only “Zg9092”...
  • Page 6 ProductURL string, bitmap8, NameSupport 0x000B 0x0000 NULL read-only read-only 0, not supported Sw build id string, 0x4000 Command supported: 6.9.1.0_r4 read-only Command Description Command supported: Add Group Command Description 0x00 Adds the endpoint to a group. Reset to Factory Defaults Command View Group On receipt of this command, the device resets all the attributes of all its clusters to their 0x00...
  • Page 7 OperateDisplayLcdBrightnesss Away Mode Set: ENUM8 OLED brightness when operate the buttons: 0x2002 0x1224 Value=0: not away (default) reportable ENUM8, Value=0 : Low Level Value=1: away 0x1000 0x1224 reportable Value=1 : Mid Level(default) Command supported: Value=2 : High Level Command Description ButtonVibrationLevel Setpoint Raise/Lower Key beep volume &...
  • Page 8 int16U, Occupancy ACCurrentMultiplier 0x0602 read-only Bit 0 specifies the sensed occupancy as follows: 1 = occupied, 0 = unoccupied. bitmap8 , 0x0000 This flag bit will affect the Occupancy attribute of HVAC cluster, and the ACCurrentDivisor operation mode. int16U, Used together with above attributes, the real displayed current = RMSCurrent 0x0603 read-only * ACCurrentMultiplier...
  • Page 9 The temperature schedule of auto mode (energy save mode) is not configured correctly 3. Current temperature is not executed when away mode is selected Check whether away mode time is set as 0 or within valid time range SR-ZG9092A SR-ZG9092A 4. Over heat alarm when power on the device...