Sunricher SR-ZV9092A Quick Start Manual

Sunricher SR-ZV9092A Quick Start Manual

Z-wave heating thermostat

Advertisement

Z-Wave Heating Thermostat SR-ZV9092A
Important: Read All Instructions Prior to Installation
Function introduction
LED Display
TIME/SHIFT button, to set
time schedule of the
device quickly and move
the cursor
Mode button, to switch
operation modes and quit
10 mm 10 mm
31 mm
Floor temp sensor
DSK Label
Revised 08.21.2021
Home Interface
Function button, to
confirm, save setting
Move up and move down
F
buttons
Front side
80 mm
59 mm
SR-ZV9092A
NTC
L
L N N
AC Power input
Output
Back side
Product Data
Z-Wave Frequency
868.42MHz (EU)
Input Voltage
EU: AC200-240V, 50/60Hz
Output Voltage
EU: AC200-240V
3680W @ 230V (resistive load)
Max Load
Max Current
16A
Power Consumption
<2W
Ambient Temperature
0°C to 40°C (during operation)
Set Temperature Range
0°C to 40°C
Hysteresis
0.5°C to 2°C (default 0.5°C)
1. NTC/10K B(25/50℃)=3950 (default)
2. NTC/15K B(25/50℃)=3950
Floor sensor type
3. NTC/50K B(25/50℃)=3950
4. NTC/100K B(25/50℃)=3950
OFF, HEAT, ENERGY HEAT, AWAY, DRY
Control Mode
Control type means which temperature sensor the device refers to
when it adjust temperature.
Room sensor: adjust temperature refers to room temperature
(factory default type).
Control Type
Floor sensor: adjust temperature refers to floor temperature.
Room+Floor sensor: adjust temperature refers to both room
temperature and floor temperature.
Current ≤ 13A - 1.5mm² solid core wire
Wiring Requirement
Current > 13A to 16A - 2.5mm² solid core wire
IP Rating
IP21
Control Pollution Degree (Method D)
pollution degree 2
Rated Impulse Voltage (Method D)
4kV
Relative Humidity
8% to 80%
Dimensions
80x80x52mm
Z-Wave Plus™,CE,
LVD: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1
EMC & RF: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,
EN 60730-1:2016+A1:2019, EN 60730-2-
Approvals
19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-
1V2.2.3, ETSI EN301 489-3V2.1.1
ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1
RED certificate: 2014/53/EU
•The Z-Wave™ HVAC controller is a wireless thermostat for heating system, which complies to Z-Wave Plus™
wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and
locally or through remote controlled through Z-Wave primary controller (gateway).
Ty

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SR-ZV9092A and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunricher SR-ZV9092A

  • Page 1 Z-Wave Heating Thermostat SR-ZV9092A Product Data Revised 08.21.2021 Z-Wave Frequency 868.42MHz (EU) Input Voltage EU: AC200-240V, 50/60Hz Important: Read All Instructions Prior to Installation Output Voltage EU: AC200-240V Function introduction 3680W @ 230V (resistive load) Max Load Max Current Power Consumption <2W...
  • Page 2: Heating Status

    •The thermostat can be included and operated in any Z-Wave™ network with other Z-Wave certified devices mode will be selected, or just short press button to select a desired mode when the modes’ icon displayed from other manufacturers and/or other applications. All non-battery operated nodes within the network will act alternatively.Press and hold button on Home interface for over 3 seconds to select Away mode directly, as repeaters regardless of vendor to increase reliability of the network.
  • Page 3: Monitor Set

    Schedule setting method 2: on Home Interface, meanwhile the device is under Auto Mode , short press Short press button to select the item would like to modify, then short press button to enter into Auto Mode Schedule weekly setting interface quickly: move up and move down buttons to modify value of selected item, then On Auto Mode Schedule weekly setting interface, use buttons...
  • Page 4 8.TIME/DATE SET Display Temp type (Home Temp by default) Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow: This parameter defines which sensor temperature will be displayed on Home page. Short press button to select the item would like to modify, then short Floor Temp: floor temperature (external sensor).
  • Page 5 no response from a gateway within 6 seconds, or exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”. COMMAND_CLASS_THERMOSTAT_MODE Note 1: if the device is excluded or reset successfully, the Auto Mode Schedule will be reset to default value. COMMAND_CLASS_THERMOSTAT_OPERATING_STATE Note 2: the sent frame of inclusion and exclusion is INFO frame.
  • Page 6 Whether to recover to settings before power failure or power reset Support command class Support S2/s0 0, use default settings 0x04(4) Other Set COMMAND_CLASS_ZWAVEPLUS_INFO 1, recover to settings before power failure or power reset COMMAND_CLASS_SECURITY High temperature detection max. value, unit is ℃ , when either temperature sensor is higher than this value, the device will turn off the relay and send NOTIFICATION COMMAND_CLASS_SECURITY_2 0x06(6)
  • Page 7: Wiring Diagram

    +12 ~ -12 (energy save mode) is not configured correctly. Window open detect function temperature threshold: the Celsius degrees that the SR-ZV9092A 3. Current temperature is not executed when away mode is temperature decreases within 3 minutes, unit is 0.1 Celsius degree.

Table of Contents