Indicator Light - Battery Power Saving Mode; Low Oil Shutdown; Do Not Overload Generator - Firman H05753 Owner's Manual

Dual fuel generator
Hide thumbs Also See for H05753:
Table of Contents

Advertisement

Available languages

Available languages

If a cover is used, do not install until unit has cooled.
NOTE: Disconnect the LPG cylinder from the
generator during transportation.
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or
explosion resulting in death, serious injury
and/or property damage.
DO NOT stop engine by moving choke control
to "START" position.
Important: Always ensure that the
switch
is in the "OFF" position when the engine
is not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.

Indicator light - Battery Power Saving Mode

This generator is equipped with an electronic
module which consumes battery power. When
the fuel selector switch is turned to the "GAS" or
"LPG" position, the indicator light will become
RED up to 4 minutes(before goes off).
Starting the engine successfully during these 4
minutes will turn the indicator light GREEN.
Starting the engine unsuccessfully or not attempting
to start the engine at all during these 4 minutes will
switch generator to Battery Power Saving Mode in
order to conserve and increase the life of battery.
MUST HAVE SOLID RED INDICATOR LIGHT TO
BE ABLE TO START THE GENERATOR. THE GENERATOR
CANNOT BE STARTED DURING BATTERY POWER
SAVING MODE UNLESS THE FUEL SELECTOR SWITCH
IS TURNED TO THE "OFF" POSITION AND THEN
TURNED BACK TO THE "GAS" OR "LPG" POSITION.
Unwanted Shutdown:
The indicator light will start FLASHING for 4
minutes in the event of any unwanted shutdown
such as low oil, running out of fuel(gasoline or LPG),
or any other unwanted shutdown. This is a reminder
that the generator is switching to Battery Power
Saving Mode. The generator should be checked
English
for any unwanted shutdown.
The generator cannot be started during or after
the 4 minutes of FLASHING mode unless the fuel
selector switch is turned to the "OFF" position and
then turned back to the "GAS" or "LPG" position.
This generator is equipped with an automatic
battery charging circuit and the battery will
receive a proper charge when the engine is
running to keep the battery charged.

Low Oil Shutdown

If the engine oil drops below a preset level, an
fuel selector
oil switch will stop the engine. Check oil level
with dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is
corrected.
If oil level is below LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again
a low oil condition may still exist. DO NOT try
to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.

Do Not Overload Generator

Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1. Start the generator with no electrical load
attached.
2. Allow the engine to run for several minutes
to stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Page 25
Customer Service: 1-844-FIRMAN1

Advertisement

Table of Contents
loading

Table of Contents