Starting the Generator (Recoil Start-Gasoline)

1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level and fuel(Gasoline).
3. Make sure the LPG cylinder knob is fully closed.
4. Turn the fuel selector switch to "GAS" position.
NOTE: When the fuel selector switch is turned
to the "GAS" position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
5. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
6. Move choke lever located on engine to "START"
position.
English
7. Pull the starter cord slowly until resistance is
felt and then pull rapidly.
REMINDER: MUST HAVE SOLID RED INDICATOR
LIGHT TO BE ABLE TO START THE GENERATOR.
THE GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
THE FUEL SELECTOR SWITCH IS TURNED TO
THE "OFF" POSITION AND THEN TURNED
BACK TO THE "GAS" POSITION.
See Indicator light-Battery power Saving
Mode section for more information.
8. Do not over-choke. As soon as engine starts
and warms up, move the choke lever to the
"RUN" position.
9. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
Starting the Generator (Recoil Start-LPG]
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level .
Page 20
Customer Service: 1-844-FIRMAN1