Ec Declaration Of Conformity; General Power Tool Safety Warnings; Save All Warnings And Instruc- Tions For Future Reference - Makita DHR283 Instruction Manual

Cordless combination hammer
Hide thumbs Also See for DHR283:
Table of Contents

Advertisement

Model DHR281 with DX09
Sound pressure level (L
Sound power level (L
) : 103 dB (A)
WA
Uncertainty (K) : 3 dB(A)
Model DHR282 with DX08
Sound pressure level (L
Sound power level (L
) : 103 dB (A)
WA
Uncertainty (K) : 3 dB(A)
Model DHR283 with DX09
Sound pressure level (L
Sound power level (L
) : 103 dB (A)
WA
Uncertainty (K) : 3 dB(A)
WARNING:
Wear ear protection.
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to EN60745-2-6:
Model DHR280
Work mode: hammer drilling into concrete
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: hammer drilling into concrete with DX08
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: chiselling function with side grip
Vibration emission (a
h, Cheq
Uncertainty (K) : 1.5 m/s
Work mode: drilling into metal
Vibration emission (a
) : 2.5 m/s
h,D
Uncertainty (K) : 1.5 m/s
Model DHR281
Work mode: hammer drilling into concrete
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: hammer drilling into concrete with DX09
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: chiselling function with side grip
Vibration emission (a
h, Cheq
Uncertainty (K) : 1.5 m/s
Work mode: drilling into metal
Vibration emission (a
) : 2.5 m/s
h,D
Uncertainty (K) : 1.5 m/s
Model DHR282
Work mode: hammer drilling into concrete
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: hammer drilling into concrete with DX08
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: chiselling function with side grip
Vibration emission (a
h, Cheq
Uncertainty (K) : 1.5 m/s
Work mode: drilling into metal
Vibration emission (a
) : 2.5 m/s
h,D
Uncertainty (K) : 1.5 m/s
Model DHR283
Work mode: hammer drilling into concrete
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
Work mode: hammer drilling into concrete with DX09
Vibration emission (a
h, HD
Uncertainty (K) : 1.5 m/s
) : 92 dB(A)
pA
) : 92 dB(A)
pA
) : 92 dB(A)
pA
2
): 9.0 m/s
2
2
): 8.0 m/s
2
2
): 8.5 m/s
2
2
2
2
): 9.5 m/s
2
2
): 8.0 m/s
2
2
): 9.0 m/s
2
2
2
2
): 9.0 m/s
2
2
): 8.0 m/s
2
2
): 8.0 m/s
2
2
2
2
): 9.5 m/s
2
2
): 8.0 m/s
2
Work mode: chiselling function with side grip
Vibration emission (a
Uncertainty (K) : 1.5 m/s
Work mode: drilling into metal
Vibration emission (a
Uncertainty (K) : 1.5 m/s
NOTE: The declared vibration emission value has been
measured in accordance with the standard test method
and may be used for comparing one tool with another.
NOTE: The declared vibration emission value may
also be used in a preliminary assessment of exposure.
WARNING:
The vibration emission during actual
use of the power tool can differ from the declared emission
value depending on the ways in which the tool is used.
WARNING:
Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it is
running idle in addition to the trigger time).

EC Declaration of Conformity

For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS

General power tool safety warnings

WARNING:
Read all safety warnings, instruc-
tions, illustrations and specifications provided
with this power tool. Failure to follow all instructions
listed below may result in electric shock, fire and/or
serious injury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1.
Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
Do not operate power tools in explosive atmo-
2.
spheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
3.
Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
Electrical Safety
1.
Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
3 ENGLISH
2
): 8.5 m/s
h, Cheq
2
2
) : 2.5 m/s
h,D
2

Advertisement

Table of Contents
loading

Table of Contents