Removing The Collected Water - Toshiba TDDP5012ES2C Owner's Manual & Installation Manual

Hide thumbs Also See for TDDP5012ES2C:
Table of Contents

Advertisement

Removing the collected water

There are three ways to remove collected water.
1. Use the bucket
When the bucket is full, remover the bucket and empty it.
Note: If the pump hose drops when you remove the bucket , you must reinstall the pump hose properly to the
unit before replace the bucket into the unit.
2. Continuous draining
Water can be automatically emptied into a floor drain by attaching the unit with a water hose (Id≥Φ 5/16", not
included)with a female threaded end (ID:M=1", not included).
· Drain hose subassembly: Install the drain hose onto the adaptor A
(placed in the bucket).
· Remove the plastic cover from the back drain outlet of the unit and
set aside and remove bucket,then insert the drain hose
through the drain outlet of the unit and securely press it into
the connector on the front of the unit. Tighten the adaptor A
and the unit by using two screws (placed in the bucket).
· Install the female threaded end of the water hose into the
adaptor A, then lead the water hose to the floor drain or a suitable drainage facility.
Female
threaded
end
Water hose
3.Pump draining (on some models)
Water can be automatically emptied into a floor drain or a suitable drainage facility by attaching the pump
drain out with a pump drain hose (od=Φ1/4", supplied).
Note: The pump operation on light blinks at 1Hz when
the pump is operational failure. Please turn off the unit
and plug the power cord out. Check the following
things: Cleaning the filter of the pump.
Page 14
Pump hose drops
Note:
· Make sure the connection is tight and there is no leak.
· Lead the water hose to the floor drain or a suitable drainage facility, the drainage
facility should be lower than the drain outlet of the unit.
· Be sure to run the water hose sloping downward to let the water flow out smoothly.
· When the continuous drain feature is not being used, remove the drain hose from the
outlet.
water outlet
Reinstall pump
hose properly
Drain hose
Plastic cover
Drain hose
subassembly
Reinstall the Plastic cover by
using two screws.
Remove the drain hose
and drain hose subassembly.
insert pump drain hose to
the drain hose outlet
AdaptorA
Connector
Drain hose
Pump drain
hose outlet