Samsung AS24UUQ User & Installation Manual page 24

Table of Contents

Advertisement

Choosing the installation location
Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Out of the direct sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong enough to hold the product weight
3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
Install the unit horizontally
Place where drained water does not become any problem.
Place with no plants (especially climbing plants) and where small animal can not access.
• Avoid the following places to prevent malfunction of the unit
- Where there is machine oil
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
Min
Recommended
Space
**
09/12
A
300
30
B
125
50
C
125
50
Wrap the refrigerant pipes and the drain
hose with the absorbent pad and vinyl
tape. Refer to page 36 for further details.
300mm
minimum
600mm
minimum
24
- Salty environment such as seaside areas
- Other special atmosphere areas
Unit : mm
Min
**
**
**
18/24
100
100
' B '
100
You can select the direction
of draining (left or right).
' L ' meters maximum
total pipe length
600mm
minimum
300mm
minimum
Make at least one round: It will reduce noise and vibration
' A '
' C '
' H ' meters maximum
total pipe height
Model
L
H
09
15
7
** **
**
12
**
15
7
18
**
**
15
7
**
24
**
20
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

As12u seriesAs18u seriesAs24u seriesAs09u series

Table of Contents