Checking before use

Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can
be operated within.
Refer to the table for efficient use.
MODE
2.6kW
3.5kW
COOLING
5.2kW
6.0kW
7.1kW
2.6kW
3.5kW
HEATING
5.2kW
6.0kW
7.1kW
2.6kW
3.5kW
DRYING
5.2kW
6.0kW
7.1kW
Model : AJ
Mode
Outdoor temperature
Cooling
-5˚C/23˚F ~46˚C/115˚F 16˚C/61˚F~32˚C/90˚F
Heating
-15˚C/5˚F~24˚C/75˚F
Dry
-5˚C/23˚F~46˚C/115˚F 18˚C/64˚F~32˚C/90˚F
• T he standardized temperature for heating is 7˚C/45˚F. If the outdoor temperature drops to 0˚C/32˚F or below, the
heating capacity can be reduced depending on the temperature condition.
NOTE
If the cooling operation is used at over 32˚C/90˚F (indoor temperature), it does not cool at its full capacity.
• T he use of the air conditioner at a relative humidity above the expected one (80%)
may cause the formation of condensate and the leakage of water drops on the
CAUTION
floor.
OUTDOOR TEMPERATURE
-10°C/14°F to 46°C/115°F
-15°C/5°F to 46°C/115°F
-15°C/5°F to 50°C/122°F
-15°C/5°F to 24°C/75°F
-20°C/-4°F to 24°C/75°F
-10°C/14°F to 46°C/115°F
-15°C/5°F to 46°C/115°F
-15°C/5°F to 50°C/122°F
Indoor
temperature
27˚C/81˚F or less
INDOOR TEMPERATURE
18°C/64°F to 32°C/90°F
27°C/81°F to less
18°C/64°F to 32°C/90°F
Indoor humidity
Condensation may occur on the indoor
80% or less
unit with risk to have either water blow
off or drop on the floor.
Internal protection triggers and the air
-
conditioner will stop.
Condensation may occur on the indoor
-
unit with risk to have either water blow
off or drop on the floor.
INDOOR HUMIDITY
80% or less
If out of conditions
9