Troubleshooting - LG LCV900B Owner's Manual

Petcare plus canister vacuum cleaner
Hide thumbs Also See for LCV900B:
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Musty or unusual smell
Agitator does not turn
POSSIBLE CAUSE
• Smell of new motor
• Old and dirty filters
• The foam filter or exhaust
filter is wet.
• Switch is off (unit is in
bare floor mode)
• The power nozzle is
disconnected with the
wand.
• Agitator motor overload
protection is tripped
(brush is jammed)
• Belt broken
• The wand is disconnected
with the hose.

TROUBLESHOOTING

POSSIBLE SOLUTION
• New vacuum cleaner smell should
disappear in 1-2 months.
• Empty dust tank and clean filters.
• Dry the foam filter or exhaust filter
completely away from sunlight.
• Turn on agitator power switch.
• Properly connect the power nozzle to the
wand.
• Unplug the vacuum cleaner and check the
agitator for obstructions and reset the unit.
• Replace belt.
• Properly connect the wand to the hose.
23

Advertisement

Table of Contents
loading

Table of Contents