Velleman DCM115 User Manual page 9

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
9.2 AC VOLTAGE
range
750 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40 Hz-500 Hz
Overload protection: 1000 V DC or 750 V AC rms
Impedance: 10 MΩ
9.3 AC CURRENT
range
200 A
1000 A
Average sensing, calibrated to rms of sine wave
Frequency range: 40 Hz-500 Hz
Overload protection: 1200 A rms within 60 sec
9.4 RESISTANCE
range
200 Ω
20 kΩ
Overload protection: 250 V DC or AC rms
V. 01 – 06/08/2018
Do not measure circuits that may contain voltages
> 1000 VDC or > 750 VAC
resolution
1 V
Do not measure circuits that may contain voltages
> 1000 VDC or > 750 VAC
resolution
0.1 A
1 A
Do not conduct resistance measurements on live
resolution
0.1 Ω
10 Ω
DCM115
accuracy
± (1.0 % rdg + 3 digits)
accuracy
± (2.0 % rdg + 5 digits)
± (2.5 % rdg + 5 digits) (≤ 800 A)
± (3.0 % rdg + 5 digits) (> 800 A)
circuits
accuracy
± (1.0 % rdg + 3 digits)
9
©Velleman nv

Advertisement

Table of Contents
loading

Table of Contents