10.5 INSULATION
Do not conduct insulation measurements on live circuits. Make sure
all capacitors in the circuit are depleted.
Set the rotary switch in the "EXTERNAL UNIT" position.
1.
Connect the insulation tester unit to the "V", "COM" and "EXT" jacks.
2.
3.
Switch on the insulation tester.
4.
Connect the test leads to the source being measured.
5.
Read the value on the LCD display.
10.6 DATA HOLD
Press "DATA HOLD" to lock the displayed value. Press again to exit.

11. Battery Replacement

WARNING: To avoid electrical shock always disconnect the test
leads prior to opening the housing. To prevent fire hazards, only use
fuses with the same ratings as specified in this manual.
Remark: refer to the warning on the battery compartment
There are no user-serviceable parts inside the device.
Refer to an authorized dealer for service and/or spare parts.
Disconnect the test leads from the test points and remove the test
leads from the measuring terminals before replacing the batteries or
fuses.
When"
" is displayed, the battery should be replaced.
Fuses rarely need replacement and blown fuses almost always result
from human error.
To replace the battery:
Switch of the meter.
Remove the screw at the back of the case and gently open the housing.
Remove the old battery and insert a new one.
Close the housing and fasten the screw.
Battery: 2x AAA/R03, make sure to respect the polarity

12. Troubleshooting

If the device acts abnormal while measuring, this means that the internal
fuse is defective.
Keep in mind that a low battery level could lead to incorrect measurements.
Replace the battery on a regular basis.
(tip: the reduced luminosity of the backlight/LCD display indicates a low
battery level)