Operation; Operating Procedures - FCI HT-0102 Manual

Table of Contents

Advertisement

D. Specifications (continued)
Strip Length of Insulation:
• Latch Housing and
Discrete Applications ................... 3.81-4.32 mm
Wire Barrel Crimp Height:
• Single Wire (28-32 AWG)
Or Double Wires
(30-32 AWG) ............................... 0.61-0.66 mm
• Single Wire (22-26 AWG)
Or Double Wires
(26-28 AWG) ............................... 0.76-0.81 mm
Insulation Barrel Crimp Height:
• "A" Side (28-32 AWG)
Latch Housing and
Discrete Applications ................. 1.75 mm
• "B" Side (22-26 AWG)
Latch Housing and
Discrete Applications ................... 1.75 mm
Male Pin Terminals:
• Loose Piece....................................... 22-32 AWG
NOTE
Loose piece terminals have different part
numbers than reeled terminals
CAUTION
If the terminal and the tooling are not compatible,
damage to the tooling could result. If you wish to use a
terminal with a part number other than the one that
was ordered for the HT-0102 check with your
distributor or FCI Electronics to be sure that the new
terminal number is compatible with your hand tool.
II. OPERATION
A. Operating Procedures
WARNING
To prevent hand injury, keep fingers from between
the upper and lower tooling and from between the
lever and handle when closing hand tool.
1. Hold the hand tool so that the lever is on the left.
With your index finger, push and hold the terminal
holder in its forward position (see Figure 2).
FCI Electronics
Issued: Date (10/24/94)
Rev. 03/08/01 ECR V103118
K\DCU\Manuals
ELECTRONICS
(0.150-0.170 in.)
(0.024-0.026 in.)
(0.030-0.032 in.)
(0.069 in.) Max. Dia.
(0.069 in.) Max. Dia.
PDM: Rev:B
NOTE
When inserting a terminal into the terminal holder
you will notice a slight drag (interference) on the
terminal. The drag is caused by the spring ball
plunger (see Figure 13 item no. 21) applying
downward pressure on the pin end of the terminal.
This downward pressure helps to orient and hold
the terminal in the terminal holder until crimped
2. Insert the pin end of the terminal, with "U" shaped
barrels up, into the terminal holder and against the
pin shoulder. While holding the terminal against
the shoulder, release the terminal holder. This
ensures that the terminal remains in the proper
position while moving over the anvil.
Figure 2. Positioning Terminal for Crimping
Manual Part No. 144000-001
Page 4 of 10
Revision B
Released
STATUS:
.
Printed: Dec 20, 2002

Advertisement