LG M3204CCBA Owner's Manual page 69

Monitor signage
Hide thumbs Also See for M3204CCBA:
Table of Contents

Advertisement

RS-232C
Transmission / Receiving Protocol
16. Abnormal state (Command : z)
► Abnormal State : Used to Read the power off status when Stand-by mode.
Transmission
[k][z][ ][Set ID][ ][Data][Cr]
Data FF : Read
Acknowledgement
[z][ ][Set ID][ ][OK][Data][x]
0 : Normal (Power on and signal exist)
1 : No signal (Power on)
2 : Turn the monitor off by remote control
3 : Turn the monitor off by sleep time function
4 : Turn the monitor off by RS-232C function
8 : Turn the monitor off by off time function
9 : Turn the monitor off by auto off function
17. ISM mode(Command: j p)
► Used to select the afterimage preventing function.
Transmission
[j][p][ ][Set ID][ ][Data][Cr]
Data 1H : Inversion
2H : Orbiter
4H : White Wash
8H : Normal
Acknowledgement
[p][ ][Set ID][ ][OK][Data][x]
Controlling the Multiple Product
A12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M4716ccbaM3204cM4716c