Scope of delivery

After unpacking all parts, check for any damage in
transit.
If you have any complaints, please contact the dealer
from whom you purchased the appliance or our
customer service.
The delivery consists of the following parts:
Built-in appliance
Interior fittings (depending on model)
Operating instructions
Installation manual
Customer service booklet
Warranty enclosure
Information on the energy consumption and noises
Bag containing installation materials

Connecting the appliance

After installing the appliance, wait at least 1 hour until
the appliance is switched on. During transportation
the oil in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
"Cleaning the appliance").
Water connection
ã=
Caution
Connect the appliance to a drinking water line.
The water may be connected only by a competent fitter
according to the local regulations of the appropriate
water supply company.
A cold water connection is necessary for operating
the automatic ice maker. The water pressure must be
between 0.17 MPa and 10 MPa (1.7 and 10 bar). The
installation must correspond to the local plumbing
regulations.
A separate shut-off valve should be installed in
the cold-water inflow.
The shut-off valve should not be located behind
the appliance. It is recommended that you mount
the shut-off valve directly next to the appliance or at
another place which is easily accessible.
When installing the water connection, pay attention to
the permissible installation area for the water mains.
For connection to the drinking water mains use only
water pipes which are suitable for drinking water.
Observe national regulations and the connection
conditions of the local water supply companies.
The maximum outside diameter of the water mains
(without connecting pieces) is 10 mm.
Electrical connection
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with the protection class I.
Connect the appliance to 220-240 V/50 Hz alternating
current via a correctly installed socket with protective
conductor. The socket must be fused with a 10 to 16 A
fuse.
For appliances operated in non-European countries,
the identification plate should be checked whether
the electric supply and the current model stated match
the values of the mains supply. The rating plate is
situated in the bottom left-hand side of the appliance.
ã=
Warning
Never connect the appliance to electronic energy saver
plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters are used
for photovoltaic systems which are connected directly
to the national grid. Sine-controlled inverters must be
used for isolated applications (e.g. on ships or in
mountain lodges) which are not connected directly to
the national grid.