Siemens FI24 Series Instructions For Use Manual page 20

Hide thumbs Also See for FI24 Series:
Table of Contents

Advertisement

en
Ice maker
Fault
The ice maker doesn't work.
The ice maker does not make
enough ice or the ice is
deformed.
The ice maker does not make
any ice.
Ice forms in the inflow hose
to the ice maker.
Water runs from the appliance. The water connection hose is not
20
Possible cause
Ice maker is not connected to
the mains supply.
Ice maker does not contain any fresh
water.
The freezer compartment temperature
is too warm.
The appliance or ice maker has only
just been switched on.
A lot of ice has been taken.
Low water pressure.
The water filter is bunged up or used. Change the water filter.
Temperature in the freezer
compartment is too warm.
The ice maker is switched off.
The appliance is not supplied with
water.
Water supply has kinks.
Low water pressure.
Temperature in the freezer space is
too warm.
Ice cube container is not properly
inserted.
Incorrect shut-off tap installed.
Low water pressure.
Shut-off valve incorrectly opened.
properly sealed.
Incorrect shut-off tap installed.
Remedial action
Call customer service.
Ensure that the water is properly connected.
Check freezer compartment temperature
and, if required, set slightly colder.
Approx. 24 hours is needed until ice
production starts.
Approx. 24 hours is needed until the ice
cube container is filled again.
Connect the appliance to the stipulated
water pressure only (see chapter
Connecting the appliance, section Water
connection).
Set temperature slightly colder in the freezer
compartment.
Switch the ice maker on at the control panel.
Contact the installer or the water supply
company.
Turn off the water supply at the shut-off tap.
Smoothen out the kinks, exchange where
necessary.
Connect the appliance to the stipulated
water pressure only (see chapter
Connecting appliance, section Water
connection).
Set temperature slightly colder in the freezer
compartment.
Check the position, re-insert where
necessary.
Incorrect taps can cause low water pressure
and damage to the appliance.
Connect the appliance to the stipulated
water pressure only (see chapter
Connecting the appliance, section Water
connection).
Open shut-off valve fully.
Replace the hose with a manufacturer's
original part.
Incorrect taps can cause low water pressure
and damage to the appliance.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fi18 seriesFi18np31Fi18np31/10Fi18np31/12Fi18np31/11

Table of Contents