Smeg LBW362PCIT User Manual page 29

Table of Contents

Advertisement

CHAPTER -3: INSTALLATION OF THE MACHINE
(WATER INLET HOSE CONNECTION)
• Your machine may have either a single inlet (cold) or double
water inlets (cold/hot) based on its specifications.
White-capped hose should be connected to cold water inlet and
red-capped hose to hot water inlet (applicable for machines with
double water inlets).
• To eliminate water leakages in points of contact, 1 or 2 nuts are
provided in the hose package (applicable for machines with dou-
ble water inlets).
Fit these nuts to the ends of new water inlet hoses on the side of
3/4"
faucet.
• Mount new water inlet hoses to a ¾ ˝, threaded faucet.
• Connect the white-elbow end of the water inlet hoses to the
white-filtered water inlet valve on the rear side of the machine and
the red-elbow end to red-filtered one (applicable for machines with
double water inlets).
Tighten plastic parts of the junctions using your hand.
In uncertain conditions, have the connection works be done by a
qualified plumber.
• Flow of water with pressure of 0,1-1 Mpa will allow your machine
to operate more efficiently.) (0,1 Mpa pressure means that more
than 8 litres of water will flow through a fully-tapped faucet per one
minute.)
• Ensure that points of contact do not leak by tapping the faucet
completely after carrying making the connections.
EN -29-