BURNER
Grill
Gas burners for LPG G30 50 mbar
NORMAL
BURNER
POWER KW
Triple Crown
Rapid
Semi-rapid
Auxiliary
Oven
Grill
Gas connection
WARNING!
Use this appliance with the LPG
supply at a pressure of 50 mbar. If you
supply the appliance with a lower
pressure, the performance of the
appliance will be not satisfactory.
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not
used must be clogged with the pipe closer,
which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible
metallic pipes, make sure they do not come
in touch with mobile parts and they are not
squeezed.
GAS RATE G/H
4.0
290.8
3.0
218.1
2.0
145.4
1.0
72.7
3.9
283.6
2.5
181.8
Ø BYPASS 1/100 MM
55
REDUCED POWER
KW
1.6
0.72
0.43
0.35
1.5
1.6
Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
• it can not get hotter than room
temperature, higher than 30 °C,
INSTALLATION
INJECTOR MARK
1/100 MM
94
77
60
43
87
68
31