Fig. 12
5.
If nail still can not be removed, remove
the magazine:
a.
Remove screws (N).
b.
Remove magazine.
c.
Remove bent nail.
d.
Reassemble in reverse order.
nOTe: Should nails continue to jam
frequently in nosepiece, have tool serviced
by an authorized PORTER-CABLE service center.

COlD WeATHeR OpeRATIOn

When operating tools at temperatures below freezing:
1.
Make sure compressor tanks have been properly drained prior to use.
2.
Keep tool as warm as possible prior to use.
3.
Make certain all fasteners have been removed from magazine.
4.
Put 5 to 7 drops of PORTER-CABLE pneumatic tool oil in the air inlet.
5.
Lower air pressure to 80 psi (5.5 bar) or less.
6.
Reconnect air and load nails into magazine.
7.
Actuate the tool 5 or 6 times into scrap lumber to lubricate O-rings.
8.
Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal.
9.
Re-lubricate at least once daily.
10. Always drain the compressor tanks at least once a day.

HOT WeATHeR OpeRATIOn

Tool should operate normally. However, keep tool out of direct sunlight as excessive
heat can deteriorate bumpers, O-rings and other rubber parts resulting in increased
maintenance.