Porter-Cable FR350B Instruction Manual page 10

Round head framing nailer
Table of Contents

Advertisement

Available languages

Available languages

2.
Pull the trigger.
3.
Allow the tool to recoil from the work surface.
Contact actuation trigger -
The contact actuation trigger is intended for rapid
fastening on flat, stationary surfaces.
Using the contact actuation trigger, two methods are
available: place actuation and contact actuation.
To operate the tool using the plACe ACTUATIOn
method:
1.
Depress the contact trip against the work surface.
2.
Pull the trigger to drive the fastener.
3.
Allow the tool to recoil off the work surface
To operate the tool using the COnTACT ACTUATIOn method:
1.
Pull the trigger.
2.
Depress the contact trip against the work surface. As long as the trigger is pulled,
the tool will drive a fastener every time the contact trip is depressed. This allows
the user to rapidly drive multiple fastener in sequence.
Changing the Actuation Mode -
1.
Push the (red) trigger lock button down
2.
Rotate the (black) selectable trigger button counterclockwise
3.
Align the triangular indicator to the desired mode
For Sequential Mode
For Contact Mode
4.
Then push the trigger lock button back up to the un-locked position.
ADJUSTInG DepTH (FIG. 7)
To reduce risk of serious injury from accidental actuation when
attempting to adjust depth, ALWAYS:
• Disconnect air supply and engage trigger
lock.
• Avoid contact with trigger during adjustments.
The depth that the fastener is driven can be adjusted
using the depth adjustment wheel (G).
drive is factory adjusted. Test drive a fastener and
check depth. If a change is desired:
1.
To drive the nail shallower, rotate the depth
setting wheel (G) to the left.
2.
To drive a nail deeper, rotate the depth setting wheel (G) to the right.
The adjustment knob has detents every full turn. Test drive another fastener and check
depth. Repeat as necessary to achieve desired results. The amount of air pressure
required will vary depending on the size of the fastener and the material being fastened.
Experiment with the air pressure setting to determine the lowest setting that will
consistently perform the job at hand.
Air pressure in excess of that required can cause premature wear and/
or damage to the tool.
(Fig. 6)
The depth of
10 - ENG
Trigger lock button
Fig. 6
C
Trigger mode selector button
Fig. 7
G

Advertisement

Table of Contents
loading

This manual is also suitable for:

028877597607

Table of Contents