Table of Contents

Advertisement

Available languages

Available languages

Quick Links

RMW921
Wireless Microphone System
USER'S MANUAL
ITALIANO
ENGLISH
96MAN00921-REV.01/19

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Eikon RMW921

  • Page 1 RMW921 Wireless Microphone System USER’S MANUAL ITALIANO ENGLISH 96MAN00921-REV.01/19...
  • Page 2: Table Of Contents

    POWER SUPPLY ............................4 USER’S WARNINGS AND CE CONFORMITY ....................5 INTRODUCTION ............................6 DESCRIPTION ............................6 RMW921 RECEIVER ..........................6 RMW921 MENU OPTIONS ........................8 WM9M HANDHELD MICROPHONE TRANSMITTER ................10 WM9B BODYPACK TRANSMITTER ......................11 BATTERY REPLACEMENT ........................12 ACCESSORIES ............................12 TECHNICAL SPECIFICATION ........................13 FIG.1 ...............................
  • Page 3: Disposal Of Old Electrical & Electronic Equipment

    DISPOSAL OF OLD ELECTRICAL & ELECTRONIC EQUIPMENT This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the enviroment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
  • Page 4: Maintenance And Disclaimer

    these defects the dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed description. This warranty does not extend to damage resulting from improper installation, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned units, and when the unit has been properly used and warranty is still valid, then the unit will be replaced or repaired.
  • Page 5: User's Warnings And Ce Conformity

    LICENSING INFORMATION: • Frequency Range of RMW921: 823 – 832 MHz and 863 – 865 MHz. • A ministerial license may be required to operate this equipment in certain areas. The use of this professional wireless microphone equipment in some countries could be intended for professional use, so the licensability depends on the country it operates.
  • Page 6: Introduction

    INTRODUCTION Thank you for choosing this EIKON product and for your trust in our brand, synonymous of professionalism, accuracy, high quality and reliability. All our products are CE approved and designed for continuous use in professional systems. DESCRIPTION The RMW921 Wireless Microphone is a UHF, PLL controlled, true diversity system providing a reliable and high quality signal transmission and equipped with automatic channel scan and IR sync.
  • Page 7 This is the RF frequency selected for the receiver: it must be the same as the transmitter frequency. The frequency can be chosen in the 823-832 and 863-865 MHz frequency ranges (see RMW921 MENU OPTION for detailed operations).
  • Page 8: Rmw921 Menu Options

    RMW921 MENU OPTIONS Frequency Select “Frequency” to select the channel manually: Press to select then press The display will show the last used channel number flashing: press to change and/or press confirm, the display shows the frequency of the selected channel: Squelch Select “SQ”...
  • Page 9 RMW921 systems to set up, you must leave ON any transmitter you have already set up and synced with its receiver, except the transmitter that you want to set up, which must be off.
  • Page 10: Wm9M Handheld Microphone Transmitter

    17. IR This is the infrared sensor for receiving the channel setting from the RMW921 receiver. Expose this sensor to the receiver’s IR sensor during the frequency sync procedure (see RMW921 MENU OPTIONS).
  • Page 11: Wm9B Bodypack Transmitter

    This is the channel number: it can be set automatically using the IR sync procedure as described in RMW921 MENU OPTIONS above, or it can be set manually as described at point 20.a. b. This is the RF frequency, corresponding to the selected channel, or the channel number.
  • Page 12: Battery Replacement

    Press and hold for 3 seconds to switch on and off the transmitter. 27. IR This is the infrared sensor for receiving the channel setting from the RMW921 receiver. Expose this sensor to the receiver’s IR sensor during the frequency sync procedure (see RMW921 MENU OPTIONS).
  • Page 13: Technical Specification

    TECHNICAL SPECIFICATION RMW921 – UHF PLL 99 Channel Receiver RF Channels 99 frequency preset RF Frequency Band UHF: 823-832 MHz and 863-865 MHz RF Receiver Type PLL UHF Synthesized RF Modulation type FM (F3E) RF Sensitivity -105 dBm / 12 dB SINAD RF Image/Spurious Rejection >...
  • Page 15 AVVERTENZE PER L’UTILIZZO E CONFORMITÀ CE ................. 18 INTRODUZIONE ............................19 DESCRIZIONE............................19 RICEVITORE RMW921 ..........................19 RMW921 OPZIONI DI MENU ......................... 21 TRASMETTITORE A MANO WM9M ......................23 TRASMETTITORE BODYPACK WM9B ..................... 24 SOSTITUZIONE BATTERIE ........................25 ACCESSORI ............................. 25 SPECIFICHE TECNICHE ..........................
  • Page 16: Trattamento Del Dispositivo Elettrico Od Elettronico A Fine Vita

    TRATTAMENTO DEL DISPOSITIVO ELETTRICO OD ELETTRONICO A FINE VITA Il marchio riportato sul prodotto o sulla documentazione indica che il prodotto non deve essere smaltito con altri rifiuti domestici al termine del ciclo di vita. Per evitare eventuali danni all’ambiente si invita l’utente a separare questo prodotto da altri tipi di rifiuti e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali.
  • Page 17: Manutenzione E Limitazioni D'uso

    • La garanzia di funzionamento è di 24 mesi dopo la data di acquisto. I difetti rilevati entro il periodo di garanzia sui prodotti venduti, attribuibili a materiali difettosi o difetti di costruzione, devono essere tempestivamente segnalati al proprio rivenditore o distributore, allegando evidenza scritta della data di acquisto e descrizione del tipo di difetto riscontrato.
  • Page 18: Avvertenze Per L'utilizzo E Conformità Ce

    • La Proel S.p.A dichiara che Il radio-microfonico EIKON è conforme alla direttiva 2014 / 30/ EU Direttiva EMC & 2014 /35 / EU Direttiva LVD. •...
  • Page 19: Introduzione

    CE per utilizzazione continua in impianti di diffusione sonora. DESCRIZIONE I radiomicrofoni serie RMW921 sono sistemi UHF con frequenza controllata da PLL e doppia antenna true diversity, caratterizzati da una trasmissione affidabile e di ottima qualità e dotati di scansione automatica dei canali e sincronizzazione mediante infrarosso.
  • Page 20 Questo è il numero di canale: ci sono 99 canali RF memorizzati nella memoria del ricevitore, selezionati per evitare interferenze fra sistemi RMW921 e per rendere possibile l’utilizzo di 6 sistemi simultaneamente (vedi RMW921 MENU OPTION per maggiori dettagli).
  • Page 21: Rmw921 Opzioni Di Menu

    RMW921 OPZIONI DI MENU Frequency Scegliere “Frequency” per impostare manualmente il canale: Premere per scegliere quindi premere Il display mostrerà l’ultimo canale usato lampeggiante: premere per cambiarlo e/o premere confermarlo, il display mostra la frequenza del canale selezionato: Squelch Scegliere “SQ” per impostare il livello di soglia dello squelch:...
  • Page 22 RMW921 da impostare è necessario mantenere acceso ogni trasmettitore già impostato e sincronizzato col suo ricevitore, eccetto il trasmettitore che si vuole impostare, il quale deve essere spento.
  • Page 23: Trasmettitore A Mano Wm9M

    17. IR Questo è il sensore ad infrarosso IR per ricevere le impostazioni del canale dal ricevitore RMW921. Esporre questo sensore al sensore IR del ricevitore durante la procedura di sincronizzazione della frequenza (vedi RMW921 OPZIONI DI MENU).
  • Page 24: Trasmettitore Bodypack Wm9B

    Il display LCD display mostra varie informazioni: a. Questo è il numero di canale: può essere impostato automaticamente usando la procedura di sincronizzazione IR come spiegato in RMW921 OPZIONI DI MENU, o può essere impostato manualmente come descritto al punto 20.a.
  • Page 25: Sostituzione Batterie

    27. IR Questo è il sensore ad infrarosso IR per ricevere le impostazioni del canale dal ricevitore RMW921. Esporre questo sensore al sensore IR del ricevitore durante la procedura di sincronizzazione della frequenza (vedi RMW921 OPZIONI DI MENU). Nota: per esporre il sensore IR il coperchio deve essere rimosso.
  • Page 26: Specifiche Tecniche

    SPECIFICHE TECNICHE RMW921 – Ricevitore 99 Canali UHF PLL Canali RF 99 frequenze preimpostate Gamma di frequenze RF UHF: 823-832 MHz - 863-865 MHz Tipo di ricezione RF UHF con sintonizzatore PLL Tipo di modulazione RF FM (F3E) Sensibilità RF...
  • Page 27 FIG.1...
  • Page 28 FIG.2...
  • Page 29 FIG.3...
  • Page 32 PROEL S.p.A. (World Headquarters - Factory) Via alla Ruenia 37/43 64027 Sant’Omero (Te) – Italy Tel: +39 0861 81241 Fax: +39 0861 887862 www.eikon-audio.com...

This manual is also suitable for:

Rmw921hRmw921mRmw9mRmw9b

Table of Contents