Refrigeration Cycle; Condenser; Evaporator; Capillary Tube - LG WG8000E Service Manual

Table of Contents

Advertisement

2.4 REFRIGERATING CYCLE
CAUTION
Discharge the refrigerant system using a
Freon
TM
Recovery System.
If there is no valve to attach the recovery
system, install one (such as a WATCO A-1)
before venting the Freon
place after servicing the system.

2.4.1 CONDENSER

1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the 3 screws which fasten the
brace.(Refer to section 2.2.1)
3. Remove the screw which fastens the cover cond.
4. Remove the 5 screws which fasten the condenser
and shroud.
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
6. Remove the condenser carefully.
7. Re-install the components by referring to the
removal procedure.
(See Figure 14)

2.4.2 EVAPORATOR

1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the 2 screws which fasten the evaporator.
3. Move the evaporator sideways carefully.
(Refer to section 2.2.1)
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evaporator
connections.
5. Remove the evaporator carefully.
6. Re-install the components by referring to the
removal procedure.
(See Figure 15)

2.4.3 CAPILLARY TUBE

1. Remove the cabinet. (Refer to section 2.1.2)
2. After discharging the refrigerant completely,
unbraze the interconnecting tube at the capillary
tube.(See caution above)
3. Remove the capillary tube.
4. Re-install the components by referring to the
removal procedure.
TM
. Leave the valve in
Figure 14
Figure 15
—9—

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lwg0812acp

Table of Contents