1.4 FEATURES

• Designed for COOLING ONLY.
• Powerful and whispering cooling.
• Simple installation and service.
• Low air-intake, top cooled-air discharge.

1.5 CONTROL LOCATIONS

1.5.1 COOLING ONLY MODEL
• VENTILATION
The ventilation lever must be in the CLOSE position
in order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the
ventilation lever OPEN position.
The damper is opened and room air is exhausted.
• TEMP
Thermostat will automatically control the temperature
of the room. Select a higher number for a cooler
temperature in the room. The temperature is selected
by moving the knob to the desired position.
The 5 or 6 position is a normal setting for average
conditions.
• MODE
- Turns air conditioner off.
- Med speed fan operation without cooling.
- Low speed fan operation without cooling.
- Cooling with high speed fan operation.
- Cooling with med speed fan operation.
- Cooling with low speed fan operation.
NOTE!
Before using the air conditioner
secure the front grille with two screws
enclosed with the owner's manual.
1. Open the inlet grille downward and
remove the air filter.
2. Fasten the front grille with screws.
3. Reinstall the air filter.
4. Close the inlet grille.
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
• Built-in adjustable THERMOSTAT
• Washable one-touch filter
• Compact size
• Reliable and efficient rotary compressor is equipped.
CLOSE
Inlet Grille
- 4 -
VENT
OPEN