4. TROUBLESHOOTING GUIDE

4.1 OUTSIDE DIMENSIONS

4.2 PIPING SYSTEM

CAPILLARY TUBE
COMPRESSOR
TURBO FAN
EVAPORATOR COIL
Following is a brief description of the important components and their functions in the refrigeration system.
Refer to Fig. 31 to follow the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
EVAPORATOR COILS
COOLED
AIR
LIQUID
PRESSURE
DROP
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
3
607(23
/
)
5
ROOM AIR CONITIONER
CYCLE OF REFRIGERATION
SUCTION LINE
COMPLETE LIQUID
COOL LOW PRESSURE VAPOR
BOIL OFF POINT
ROOM AIR HEAT LOAD
MOTOR
COMPRESSOR
OIL
(LIQUID REFRIGERANT)
CAPILLARY TUBE
368(14
CONDENSER COILS
VAPOR INLET
OUTSIDE COOLING
AIR FOR REFRIGERANT
PASS THROUGH
Figure 31
- 16 -
Unit: mm(inchs)
1
/
)
2
CONDENSER COIL
FAN
MOTOR
HOT
DISCHARGED
AIR
LIQUID OUTLET
HIGH PRESSURE VAPOR
LIQUID REFRIGERANT
LOW PRESSURE VAPOR