Mitsubishi Electric PEH-RP10MYA Operation Manual

Indoor unit
Hide thumbs Also See for PEH-RP10MYA:

Advertisement

Quick Links

Air-Conditioners
INDOOR UNIT
PEH-RP8, 10MYA
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
PARA EL USUARIO
PER L'UTENTE
VOOR DE GEBRUIKER
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du climatiseur.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro della stessa.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.
DRIFTSMANUAL
Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
DRIFTSMANUAL
Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN XPH™Eø™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ Û ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰·
ÎÏÈÌ·ÙÈÛÌÔ‡.
‹fiLETME ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu elkitab›n› dikkatle okuyunuz.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в данном
руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.
FÖR ANVÄNDAREN
TIL BRUGER
PARA O UTILIZADOR
°IA TON XPH™TH
KULLANICI ‹Ç‹N
ДЛЯ ПОЛЬЗОВАТЕЛЯ

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PEH-RP10MYA

  • Page 1 Air-Conditioners INDOOR UNIT PEH-RP8, 10MYA FOR USER FÖR ANVÄNDAREN FÜR BENUTZER TIL BRUGER POUR L’UTILISATEUR PARA O UTILIZADOR PARA EL USUARIO °IA TON XPH™TH PER L’UTENTE KULLANICI ‹Ç‹N VOOR DE GEBRUIKER ДЛЯ ПОЛЬЗОВАТЕЛЯ OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2 [Fig. 2.0.1] [Fig. 2.0.2] TEMP. ON/OFF A Air outlet B Air inlet C Air filter A Wireless remote controller (option) B Remote controller [Fig. 5.0.1] [Fig. 3.0.1] ˚C CLOCK AMPM AMPM ON/OFF WARM COOL AUTO STOP MODE VANE AUTO START CHECK LOUVER TEST RUN...
  • Page 3: Table Of Contents

    Never use a piece of wire or a fuse with a higher rating than the one • Use only accessories authorized by Mitsubishi Electric and ask your specified. dealer or an authorized company to install them. If accessories are in- stalled improperly, water leakage, electric shock or fire may result.
  • Page 4: During Operation

    1.2. During operation In case of failure Warning: Caution: • Never remodel the air conditioner. Consult your dealer for any repair serv- • Do not use any sharp object to push the buttons, as this may damage the ice. Improper repair work can result in water leakage, electric shock, fire, remote controller.
  • Page 5: Operation

    3. Operation How to use the wireless remote controller Cooling (option) The air conditioner works to cool the room to the selected temperature. The fan blows air continuously at the selected speed. Replacing the Batteries and how to set the current time Drying (dehumidifying) : Disabled in the heating [Fig.
  • Page 6: On/Off

    CENTRALLY CONTROLLED 1Hr. ON OFF ˚C CLOCK CHECK FILTER CHECK MODE ˚C TEST RUN STAND BY ERROR CODE CENTRALLY CONTROLLED 1Hr. NOT AVAILABLE FUNCTION DEFROST ON OFF ˚C TEMP. ON/OFF CLOCK CHECK FILTER CHECK MODE ˚C TEST RUN STAND BY FILTER ERROR CODE FUNCTION...
  • Page 7: Room Temperature Adjustment

    3.6. Timer setting Caution: • When the air conditioner is used together with burners, thoroughly ven- • If the timer is set, the unit starts (stops) at the set time, and the time mode is tilate the area. Insufficient ventilation can result in accidents due to oxy- terminated.
  • Page 8: Others

    3.7. Others For wireless remote controller (option) AUTO STOP AUTO START : Displayed when control is executed by a separately CENTRALLY CONTROLLED D Press the button (TIMER SET). sold centralized control unit, etc. • Time can be set while the following symbol is blinking. STAND BY : Displayed from the start of heating operation until the OFF timer : V...
  • Page 9: Troubleshooting

    6. Troubleshooting Before you call out a repair man, check the following table to see whether there is • Was a distant command sent from the remote controller? a simple solution to your problem. Find out if the remote controller was used. •...
  • Page 10: Installation And Transferring Works, And Checking

    In some types of installation sites, the installation of an earth leakage breaker is mandatory. For details, consult with your dealer. 9. Specifications PEH-RP-MYA SERIES Model PEH-RP8MYA Item PEH-RP10MYA 380, 400, 415 Voltage 3N~ V 380, 400, 415 Power source Frequency 19.0...
  • Page 11 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. The product at hand is • Low Voltage Directive 73/23/EEC based on the following • Electromagnetic Compatibility Directive 89/ EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.
  • Page 12 Related Links Model Number: PEH-RP8MYA PEH-RP8-10MYA_Instruction_Book_(WT04435X01) PEH-RP8-10MYA_Installation_Manual_(WT04436X01) PEH-RP8-10MYA_Service_Manual_(MEE04K306)

This manual is also suitable for:

Peh-rp8mya

Table of Contents