Maintenance And Servicing - Cole Parmer MP-400 Series Instruction Manual

Melting point s
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
5.9 Calibration
A customer adjustment to the instruments
calibration can be performed. Please contact the
technical support department for details of the
recalibration procedure.
Email: cptechsupport@antylia.com
Tel: +44 (0)1785 810433
5.10 Adjustment of the Sample Blocks
Viewing Angle and Height.
To suit the individual operators' requirements the
sample blocks viewing angle and can be
manually adjusted between 0° and 96° in
relation to the height adjustment mechanism.
The height of the viewing block can be manually
raised to 15cm above its resting position in the
unit. Once the position has been manually set,
the sample block will remain in that position
until further adjustments are made by the
operator. Figure 4 shows the maximum angles of
adjustment.
14°
96°
Figure 4
(Adjustment angles of the sample block)
Note:- Please take care not to strain the
adjustment mechanism or use excessive
force when changing the position or angle
of the sample block.
5.11 Adjustment of the Sample Blocks
"Head Up" Display
On either side of the sample block there are two
finger adjustable screws that are used to adjust
the position of the "head up" temperature
8
display visible inside the viewing eyepiece. To
adjust the position of the display, please use the
following procedure:-
1. Turn the screw on the left hand side of the
2. Turn the screw on the right hand side of the
3. Turn the screw on the left hand side of the
6. Maintenance & Servicing
WARNING: Ensure the unit is disconnected
from the mains electricity supply before
attempting maintenance or servicing.
This equipment does not require routine
servicing. The only maintenance required is to
clean internal and external surfaces using a
damp cloth and mild detergent solution. Do not
use harsh or abrasive cleaning agents.
6.1 Repairs and Support
Any repairs or replacement of parts MUST be
82°
undertaken by suitably qualified personnel.
Only spare parts supplied or specified by
Antylia Scientific or its agents should be
used. Fitting of non-approved parts may
affect the performance and safety features
designed into the instrument.
For a comprehensive list of parts required by
service engineers conducting internal repairs
please contact the spares department quoting
the model and serial number:
Email: cpspares@antylia.com
Tel. +44 (0)1785 810222
sample block counter-clockwise to allow an
adjustment to be made.
sample block clockwise to lower the image in
the viewer or turn it counter-clockwise to
raise the image in the viewer.
sample block clockwise to secure the new
position of the "head up" image display.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp-400d03011-49

Table of Contents