LG GR-L258USJH Owner's Manual page 34

Bottom freezer refrigerator
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
(CONTINUED)
4. FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe
with the pipe clamp.
Pipe Clamp
Saddle-Type
Shutoff Valve
NOTE: Commonwealth of Massachusetts
Plumbing Codes 248CMR shall be adhered
to. Saddle valves are illegal and use is not
permitted in Massachusetts. Consult with your
licensed plumber.
5. TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing
washer begins to swell.
NOTE: Do not overtighten or you may crush
the tubing.
Pipe Clamp
Clamp Screw
6. ROUTE THE TUBING
Route the tubing between the cold water line
and the refrigerator.
Route the tubing through a hole drilled in the
wall or floor (behind the refrigerator or
adjacent base cabinet) as close to the wall as
possible.
NOTE: Be sure there is sufficient extra tubing
(about 8 feet coiled into 3 turns of about 10"
diameter) to allow the refrigerator to move out
from the wall after installation.
CONNECTING THE WATER LINE
Vertical Cold
Water Pipe
Washer
Inlet End
7. CONNECT THE TUBING TO THE
VALVE
Place the compression nut and ferrule
(sleeve) for copper tubing onto the end of the
tubing and connect it to the shutoff valve.
Make sure the tubing is fully inserted into the
valve. Tighten the compression nut securely.
Saddle-Type
Shutoff Valve
Packing Nut
Outlet Valve
NOTE: Commonwealth of Massachusetts
Plumbing Codes 248CMR shall be adhered
to. Saddle valves are illegal and use is not
permitted in Massachusetts. Consult with your
licensed plumber.
8. FLUSH OUT THE TUBING
Turn the main water
supply on and flush out
the tubing until the water
is clear.
Shut the water off at the
water valve after about
one quart of water has
been flushed through the
tubing.
34
Compression
Nut
Ferrule (sleeve)

Advertisement

Table of Contents
loading