Chapter 3 Faults; Error Indication - Gree GMV6 Series Service Manual

Dc inverter vrf units
Hide thumbs Also See for GMV6 Series:
Table of Contents

Advertisement

Gree

1 Error Indication

Error
Code
Malfunction of IDU
L0
L2
Auxiliary heating protection
L4
Abnormal Power for wired controller
L6
Mode conflict
L8
Power is insufficient
For single control over multiple units, IDU
LA
series is inconsistent (HBS network)
LC
IDU is not matching with outdoor unit
Rotation speed of EC DC water pump is
LE
abnormal
Setting of functional DIP switch code is
LJ
wrong
LU
Zero-crossing malfunction of PG motor
d1
Indoor PCB is poor
d3
Malfunction of ambient temperature sensor
Malfunction
d5
sensor
d7
Malfunction of humidity sensor
d9
Malfunction of jumper cap
Indoor
dH
PCB of wired controller is abnormal
Malfunction of air outlet temperature
dL
sensor
Malfunction of upper water temperature
dF
sensor of water tank
Malfunction of inlet tube temperature
dP
sensor of generator
db
Debugging status
dn
Malfunction of swing parts
Malfunction of entry-tube temperature
y1
sensor 2
Malfunction of fresh air inlet temperature
y7
sensor
yA
Malfunction of IFD
o2
High bus bar voltage of IDU
o4
Failure startup of IDU
o6
Current detection circuit malfunction of IDU
o8
Communication malfunction of IDU's drive
oA
High temperature of IDU's module
oC
Charging circuit malfunction of IDU

Chapter 3 Faults

Content
of
mid-tube
temperature
71
GMV6 DC Inverter VRF Units Service Manual
Error
Code
L1
Protection of indoor fan
L3
Water-full protection
L5
Freeze prevention protection
L7
No main IDU
For single control over multiple units,
L9
number of IDU is inconsistent (HBS
network)
LH
Alarm due to bad air quality
LL
Malfunction of water flow switch
LF
Malfunction of shunt valve setting
LP
Zero-crossing malfunction of PG motor
For single control over multiple units, IDU
Lb
is inconsistent (reheating-dehumidifying
system)
Malfunction of lower water temperature
d2
sensor of water tank
Malfunction of entry-tube temperature
d4
sensor
d6
Malfunction of exit-tube temperature sensor
d8
Malfunction of water temperature sensor
dA
Web address of IDU is abnormal
Setting capacity of DIP switch code is
dC
abnormal
dE
Malfunction of indoor CO
Malfunction
of
dJ
sensor
Malfunction of drainage pipe temperature
dU
sensor of generator
Malfunction of solar power temperature
dd
sensor
dy
Malfunction of water temperature sensor
Malfunction of exit-tube temperature sensor
y2
2
y8
Malfunction of IDU's air box sensor
o1
Low bus bar voltage of IDU
o3
IPM module protection of IDU
o5
Over-current protection of IDU
o7
Desynchronizing protection of IDU
Communication malfunction of main mater
o9
of IDU
Malfunction of temperature sensor of IDU's
ob
module
o0
Other drive malfunction
Content
sensor
2
backwater
temperature