Applications; Preparation Before Operation - Hitachi E24SB Safety Instructions And Instruction Manual

Table of Contents

Advertisement

English
Assembly Procedures
1. Drain the oil by removing the oil drain plug.
2. Drain the gasoline by removing the cup of fuel cock.
3. Attach the wheels 2 to the wheel-shaft 1
4. Insert the split-pin 4 into the hole that is on the wheel-shaft 1, after putting in the washer 3 to the wheel-shaft,
for the prevention of detaching the wheels 2 from the wheel-shaft 1.
5. Prepare 2 sets of the above wheel-shaft assembly.
6. Attach the wheel-shaft assembly to the frame-base, making use of the brackets 5, the bolts 6, washers 8 and
nuts 7.
7. Finally, attach the above 2 wheel-shaft assemblies to the front and rear of the frame-base.
CAUTION: For your safety, don't fail to fix the wheels with wheel brakes for the prevention of moving.
Don't operate the generator set at an inclined foundation.
Parts Number: KY90076DA

APPLICATIONS

Power source of electric appliances and tools.
WARNING: HITACHI electronic controlled products should not be used with portable generators.
Irregular generator power could cause these products to fail.
Regarding other manufacturer's products, please contact the manufacturer to see if it is
safe to use the electronic controlled products with portable generators.

PREPARATION BEFORE OPERATION

Before starting the generator, check the oil and fuel levels. Be sure that the air cleaner is functioning. Follow the
guidelines below when adding oil and fuel.
NOTE: There is no oil in the engine crankcase when the generator is shipped. You must add oil before
starting the engine. Check the oil level before each use with the generator on a level surface and
the engine stopped.
Engine oil is a major factor affecting engine performance and service life. Non-
detergent and 2-stroke oils will damage the engine and are not recommended.
Use 4-stroke motor oil that meets or exceeds the requirements for API service
classification SE or Higher.
Always check the API SERVICE label on the oil container to be sure it includes
the letters SE or Higher. SAE 10W- 30 or 10W-40 is recommended for general,
all-temperature use. Other viscosities shown in Fig.6 may be used when the
average temperature in your area is within the indicated range.
CHECKING THE OIL
1. Remove the oil filler cap and wipe the dipstick clean.
2. Check the oil level by inserting the dipstick into the filler neck without screwing
it in.
3. If the test shows no oil markings, the oil is low.
4. If the level is low, add the recommended oil to the upper mark on the dipstick.
10
Single
grade
Multi
grade
Ambient
temperature
Fig. 6
OIL FILLER CAP
(OIL GAUGE)
Fig. 7

Advertisement

Table of Contents
loading

This manual is also suitable for:

E35sbE42sb