Manual Storage; Reheat; Disinfection Operation - Daikin Altherma EKHVMRD50ABV1 Operation Manual

Table of Contents

Advertisement

Manual storage

This mode is to be selected manually and will make the indoor unit
immediately deliver hot water to the domestic hot water tank. This
mode will continue until the storage temperature set point is reached.
It is a one-time hot water making feature.
Selecting manual storage operation for domestic water heating
1
Push and hold the
button for 5 seconds to activate manual
storage operation.
The
icon will start blinking with 1 second intervals.
Remark that the
NOTE
during effective operation.
During the operation it is always possible to
cancel the operation by pushing the
once.
Be aware that after pushing the
possible that the permanently lit
displays, meaning that the reheat function is
enabled.
The storage temperature set point is a field setting. Refer to
"4.15. Field settings" on page 19
one or more field settings.
I
[b-03] set point: storage temperature (see figure
water heating modes" on page
I
[b-02] Status: defines whether the weather dependent domestic
water heating is turned ON (1) or OFF (0).
If enabled, the storage set point will be set weather dependent.
In case of a higher ambient temperature (e.g. during summer-
time), temperature of supply water to the domestic hot water
tank will be higher too, so that storage temperature set point can
be set lower in order to keep the overall equivalent hot water
amount the same during the whole year. Therefor it is
recommended to use this function.
I
[b-04] Automatic maximum domestic hot water storage
temperature: default = 70°C.
T
[b-04]
55°C
15°C
A
Ambient temperature
T
Domestic hot water storage temperature
NOTE
The ambient temperatures for weather dependent
domestic water heating (see figure) are fixed and can
not be changed.
Manual storage is deactivated automatically when the set point for
the domestic hot water storage temperature is reached. It can also be
stopped at any time by pushing the
NOTE
If weather dependent domestic water heating is
enabled [b-02], the storage temperature will be set
automatically and the field setting [b-03] will be of no
importance.
Operation manual
9
icon will only be blinking
button
button, it is
icon still
for a detailed description how to set
"Domestic
8) only valid if [b-02]=0.
A
25°C
button.

Reheat

This mode will prevent the domestic hot water from cooling down
lower than a certain temperature. When enabled the indoor unit will
deliver hot water to the domestic hot water tank when the reheat
minimum value is reached. The domestic water heating will continue
until the reheat maximum temperature is reached.
Selecting reheat operation for domestic water heating
1
Use the
button to enable reheat operation.
The
icon will display.
Remark that the
NOTE
long as the reheat function is enabled. It is not
possible to see when the indoor unit is reheating
the domestic hot water tank.
2
Press the
button again to disable reheat operation.
The
icon disappears.
The reheat minimum and reheat maximum temperature set points
are field settings. Refer to
detailed description how to set one or more field settings.
I
[b-00] Set point: reheat minimum temperature (see figure
"Domestic water heating modes" on page
I
[b-01] Set point: reheat maximum temperature (see figure
"Domestic water heating modes" on page
NOTE
Remark that pushing the
on the domestic water heating. Domestic water heating
is only switched on or off by means of the
and/or disabling the storage schedule timer.

Disinfection operation

This mode will disinfect the domestic hot water tank by periodically
heating the domestic water to a specific temperature. During the
operation of this mode the
second intervals.
NOTE
Remark that the
effective operation.
During the operation it is always possible to cancel the
disinfection function by pushing the
Be aware that after pushing the
that the permanently lit
that the reheat function is enabled.
NOTE
If a domestic hot water tank is installed, the disinfection
function is enabled by default.
The disinfection temperature set point is a field setting as are the
retention time, day and hour. Refer to
page 19
for a detailed description how to set one or more field
settings.
I
[4-00] Status: defines whether the disinfection function is turned
ON (1) or OFF (0).
I
[4-01] Operation interval: day of the week at which the domestic
water should be heated.
I
[4-02] Start time: time at which the disinfection operation is
started.
I
[5-00] Set point: Disinfection water temperature to be reached
(see figure
"Domestic water heating modes" on page
I
[5-01] Duration: time period defining how long the disinfection
set point temperature should be maintained.
Even if all schedule timers are de-activated and there is no reheat
function active, the disinfection function will operate if a domestic hot
water tank is installed and field setting [4-00] is set to ON.
icon will be continuously lit as
"4.15. Field settings" on page 19
8).
8).
button has no influence
icon will be blinking rapidly with 0.5
icon will only be blinking during
button once.
button, it is possible
icon still displays, meaning
"4.15. Field settings" on
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
Daikin Altherma indoor unit
4P404418-1 – 2015.04
for a
button
8).

Advertisement