Showtec PSA-32A12M Table of contents Warning ....................................2 Safety Instructions ................................. 2 Operating Determinations ............................4 Connection with the Three Phase Power Network ....................4 Return Procedure ................................5 Claims ....................................5 Description of the device ..............................6 Frontside..................................6 Backside ..................................
Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Your shipment includes: Showtec PSA-32A12M with the power cable (1,5 m) User manual Safety Instructions Every person involved with the installation, operation and maintenance of this device has to: ...
Page 4
If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
Showtec PSA-32A12M Operating Determinations This device is not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects. The minimum distance between light-output and the illuminated surface must be more than 0.5 meter.
Showtec PSA-32A12M Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
Showtec PSA-32A12M Description of the device Features The Showtec PSA-32A12M is a power distributor providing real-time voltage and amperage information during your show. Power distributor for 3P+ N + PE 400VAC, 32A max Road suited housing and components ...
Showtec PSA-32A12M 03) Phase L2 Main Circuit Breakers (MCB) 5 - 8 Each output has its own circuit breaker. Make sure the total load per circuit breaker does not exceed 16A and the total load per phase does not exceed 32A.
Maximum load 16A. Total load for all sockets on L3 together should not exceed 32A per phase. 17) Power input Connect to the three phase mains. Be sure the total load connected to the PSA-32A12M does not exceed 32A per phase. You can use the built-in ampere meters to check.
03) The electric power supply cables must not show any damages or material fatigue. The Showtec PSA-32A12M requires almost no maintenance. However, you should keep the unit clean. 01) Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid.
Showtec PSA-32A12M Product Specification Model: Showtec PSA-32A12M Power supply: 400V 50Hz/60Hz Max. power input: 32A/Phase Dimensions: 483 x 198 x 176 mm (LxWxH) 19 inch x 4HE (LxH) Weight: 9,70 kg Operation Input: 1,5m H07RN-F 5G6 cable + CEE male 3P+N+PE...