Centre Point CP-3DRX Instruction Manual

Multi-line laser level

Advertisement

Quick Links

C P- 3DRX
M U L T I - L I N E L A S E R L E V E L
P R E M I U M L A S E R K I T
CP-3DRX Product Code: 400106
I N S T R U C T I O N M A N U A L
1

Advertisement

Table of Contents
loading

Summary of Contents for Centre Point CP-3DRX

  • Page 1 M U L T I - L I N E L A S E R L E V E L P R E M I U M L A S E R K I T CP-3DRX Product Code: 400106 I N S T R U C T I O N M A N U A L...
  • Page 2: Laser Safety

    Laser Safety Read the following safety instructions before attempting to operate this tool. Keep these instructions in a safe place or store in the carry pouch for future reference. WARNING! SAVE ALL WARNINGS & INSTRUCTIONS FOR FUTURE REFERENCE. Read and understand all instructions. Use the tool only with the Do not position the tool near a reflective •...
  • Page 3: Item Checklist

    Item Checklist Please ensure the following items are included with your laser level. If anything is missing please contact your retailer. Centre Point Centre Point CP-DL3 Multi-purpose CP-3DRX detector & clamp mount INCHES Lithium-ion 9V Alkaline battery Laser glasses Laser target...
  • Page 4: Using The Laser

    Using the Laser Laser port Control panel Bubble vial Power / locking switch Laser port Locked position (power off) Unlocked position (power on / self levelling) Battery cover door 5/8” x 11 tripod thread 1/4” tripod thread OVERVIEW Line mode Pulse mode LINE Power indicator...
  • Page 5: Power Supply

    Using the Laser (continued) POWER SUPPLY The instrument is supplied with two • li-ion battery packs. Only one battery pack is required to operate. The instrument is also supplied with four • AA alkaline batteries as an alternative power source. Inserting or replacing the alkaline batteries Insert the alkaline batteries into the battery •...
  • Page 6: Operation

    Using the Laser (continued) SETUP Select a place as close as practical • to the work site. Ensure the location is clear of traffic. Place the laser on a level surface • such as a bench or supplied mount. OPERATION Powering on (self-levelling) To turn the instrument on, slide the power •...
  • Page 7: Using The Detector

    Using the Detector Bubble vial Direction indicators Laser sensor Power indicator Speaker indicator Power button Sound button Speaker Bubble vial FRONT OVERVIEW Direction indicators Staff clamp thread Battery compartment Battery compartment screw BACK OVERVIEW...
  • Page 8 Using the Detector (continued) POWER SUPPLY Hold the detector upright for horizontal beams • (Fig.7) or rotate 90° for vertical beams (Fig. 8). The instrument is supplied with one 9V • The LED direction indicators will indicate the alkaline battery as its standard power source. •...
  • Page 9 Using the Multi-purpose Mount Clamp Screw fixing point Magnets 1/4” thread 1/4” thread thumb screw 1/4” thread Screw fixing point 5/8” x 11 thread Height adjustment lock knob OVERVIEW Mounting onto a magnetic surface Attach the instrument to the • mount using the thumb screw.
  • Page 10 Using the Multi-purpose Mount (continued) Mounting via the clamp Attach the two mount pieces together • via the magnetic backing (Fig.10). Attach the instrument to the mount • using the thumb screw. Use the clamp to mount to a suspended •...
  • Page 11: Using The Tripod

    Using the Tripod NOT INCLUDED A tripod can be purchased from your NOTE: adjustment methods will vary on nearest measurement tool dealer. The tripod models. Always ensure that any locking below instructions are generic only and levers are unlocked before making adjustments set-up methods may vary between models.
  • Page 12: Troubleshooting

    Trouble Shooting ERROR / PROBLEM CAUSE / SOLUTION Check that the battery is charged. • Laser level does Check the battery compartment for signs of damage and not power on • ensure that the compartment and battery terminals are clean. Check that the battery is charged.
  • Page 13: Warranty

    Warranty This tool comes with a standard 3 year warranty. Extend the warranty of your laser level to 7 years by registering online. See website for terms and conditions. www.spoton.com.au/warranty-information All Spot-on measurement tools are carefully checked and tested to our precise quality assurance standards. We offer a warranty in accordance with the following conditions: 1.
  • Page 14: Specifications

    Specifications SPECIFICATIONS CP-3DRX Product code 400106 Warranty 7 Years (with online registration) Accuracy ±1.5mm at 10m Operating range 60m (with included detector) Levelling range ±4° Laser class 2 Red Battery life 10 hours + Battery type Li-ion battery pack / 4x 1.5V AA...
  • Page 15 Notes...
  • Page 16 Spot-on Laser & Tool Company Pty Ltd Spot-on Laser & Tool Company Pty Ltd reserves the right to make changes to specifications and product descriptions at any time. © Spot-on Laser & Tool Company Pty Ltd. 2021. Printed in China.

This manual is also suitable for:

400106

Table of Contents