Installation And Adjustment; Parameters - H&S AUTOSHOT HSG140 Operator's Manual

Inverter mig
Table of Contents

Advertisement

INSTALLATION AND ADJUSTMENT

§3 Installation and Adjustment
§3.1 Parameters
Model
HSG140 (115VAC)

Parameters

Input Voltage(V)
1~110/115±10%
Input Current(A)
20 (max.)
Input Power(KW)
4.2
Welding Current(A)
35~140
48
No-load Voltage(V)
40%130A
Duty cycle(40℃)
100%95A
Diameter(mm)
Fe:0.6/0.8/0.9 SS: 0.6/0.8/0.9 Flux-Cored:0.8/0.9/1.0
Protection class
IP23
Insulation class
H
Dimensions(mm)
465*214*395
12.5 Kg.
Weight(Kg)
Note: The above parameters are subject to chan.
§3.2 Duty cycle and Over-temp
The CSA/UL rated duty cycle is defined as the proportion of the time that a machine can work
continuously over a 10 minute cycle when set at 100% of rated output welding current in 40C
(104F) ambient environment.
When the transformer reaches an over-heat condition, the heat sensor inside it will open and
will output an instruction to circuit board to cut AC relay and the output welding current while
illuminating the over-heat pilot lamp in the front panel. At this time, all welding operations should
cease for 15 minutes allowing the cooling fan to reduce the temperature. The unit will auto-reset
when correct temperature has been achieved and pilot light will go out. If the machine reached
the over-temp capacity again, the welding output current or the arc cycle should be reduced.